Icom IC-R20 Instruction Manual - Page 50
Memory/bank/all bank scan
View all Icom IC-R20 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 50 highlights
7 SCAN OPERATION ■ Memory/bank/all bank scan q Select memory mode with [MR S.MW]. • Select the desired bank with [BAND] for bank scan. w Set the squelch level. eWhile pushing and holding [MODE SCAN], rotate [R-DIAL] to select the desired scanning type. • "ALL" for all bank scan; "BANK-LINK" for bank link scan or "BANK-x" for bank scan. (x= A to Z; programmed bank groups only displayed.) • Full memory scan selection [R-DIAL] -DUP TSQL AFC MODE FM ANL 146 010 MODE SCAN MR S.MW PSKIP √ µ 088 SCAN:ALL • Band link scan selection PSKIP √ µ 121 SCAN:BANK-LINK • Bank scan selection PSKIP √ µ A01 SCAN:BANK-A Selectable between "A" to "Z" if programmed r Release [MODE SCAN] to start the selected scan. • Scan pauses when a signal is received. • Rotate [R-DIAL] to change the scanning direction, or resumes manually. t To stop the scan, push [DUALWATCH]. • During memory/all/bank scan • During bank scan -DUP TSQL AFC MODE FM ANL 888 800 PSKIP √ µ 012 -DUP TSQL AFC MODE FM ANL 888 800 PSKIP √ µ P01 IMPORTANT!: To perform memory or bank scan, 2 or more memory/bank channels MUST be programmed, otherwise the scan will not start. The bank-link setting can be changed in expanded set mode. See page 58 for details. 37