    Linksys ATA Administration Guide, Version 2.0 ADMINISTRATION GUIDE
  • Linksys RTP300 | User Guide - Page 2
    Voice Supported Codecs 22 SIP Proxy Redundancy 23 Other Linksys ATA Software Features 23 Chapter 2: Basic Administration and Configuration of Your Linksys ATA Device 28 Basic Services and Equipment Required 28 Downloading Firmware 29 Basic Installation and Configuration 30 Upgrading
  • Linksys RTP300 | User Guide - Page 3
    Table of Contents Configuring NAT Mapping with STUN 40 Determining Whether the Router Uses Symmetric or Asymmetric NAT 41 Firewalls and SIP 42 Configuring SIP Timer Values 43 Chapter 4: Configuring Voice Services 44 Supported Codecs 44 Using a FAX Machine (SPA2102, SPA3102 or SPA8000)
  • Linksys RTP300 | User Guide - Page 4
    82 VoIP to PSTN Call With and Without Authentication 83 Call Forwarding to PSTN Gateway 85 Appendix A: Linksys ATA Routing Field Reference 86 Status page 86 Product Information section 86 System Status section 87 WAN Setup page 87 Internet Connection Settings section 88 Static IP
  • Linksys RTP300 | User Guide - Page 5
    Dial Plans section VoIP-To-PSTN Gateway Setup section VoIP Users and Passwords (HTTP Authentication) section Ring Settings section FXO (PSTN) Timer Values (sec) section PSTN Disconnect Detection section International Control (Settings) section User page Linksys ATA Administration Guide 109 110 110
  • Linksys RTP300 | User Guide - Page 6
    the Warning Symbol 188 General Safety Information 188 Power Safety Information 189 Appendix I: Software License Agreement 190 Software in Linksys Products: 190 Software Licenses: 190 Schedule 1 Linksys Software License Agreement 190 Schedule 2 192 Linksys ATA Administration Guide v
  • Linksys RTP300 | User Guide - Page 7
    Table of Contents Schedule 3 197 Appendix J: Contacts 200 Linksys ATA Administration Guide vi
  • Linksys RTP300 | User Guide - Page 8
    • System administrators or anyone who performs LVS installation and administration NOTE: This guide does not provide the configuration information required by specific service providers. Please consult with the service provider for specific service parameters. Linksys ATA Administration Guide vii
  • Linksys RTP300 | User Guide - Page 9
    Supported Firmware Supported Firmware This guide supports the following firmware releases. The installed firmware must be at least the indicated in the table below. Product PAP2T SPA2102 SPA3102 SPA8000 RTP300 WRP400 WAG54GP2 AG310 Firmware or system output. Linksys ATA Administration Guide viii
  • Linksys RTP300 | User Guide - Page 10
    D, "Troubleshooting" This appendix provides solutions to problems that may occur during the installation and operation of the Linksys ATA devices. Appendix E, "Environmental These appendices provide additional product information. Specifications" Appendix F, "Warranty Information" Linksys ATA
  • Linksys RTP300 | User Guide - Page 11
    • SPA9x2 series IP phones Linksys SPA9x2 Phone User Guide • Phone setup • Phone features • SPA9x2 series IP phones Linksys Voice System Installation and Configuration Guide • Network design considerations and site preparation • Switch configuration • Initial installation and configuration of the
  • Linksys RTP300 | User Guide - Page 12
    Online Resources Document Title Linksys Voice System Administration Guide Linksys Provisioning Guide Description • Administration and configuration of system features using the SPA9000 and SPA400 • Deployment options for ITSP, PSTN, and ISDN services • SPA9000, SPA400, SPA900 series phones •
  • Linksys RTP300 | User Guide - Page 13
    Open Full Acrobat Search. 3. In the Search window, complete the following steps: a. Enter the text that you want to find. b. Choose All PDF Documents in. c. From the drop-down box, choose Browse for Location. Then choose the location on your computer or local network, and click OK. Linksys ATA
  • Linksys RTP300 | User Guide - Page 14
    options you want. e. Click Search. 4. When the Results appear, click + to open a folder, and then click any link to open the file where the search terms appear. NOTE: For more information about the Find and Search functions, see the Adobe Acrobat online help. Linksys ATA Administration Guide xiii
  • Linksys RTP300 | User Guide - Page 15
    phone ports using standard analog telephone equipment. The Linksys ATA device connects to a wide area IP network, such as the Internet, through a broadband (DSL or cable) modem or router. 187254 Telephone/fax V Ethernet Broadband Linksys ATA Broadband CPE (DSL, cable, fixed wireless) Layer
  • Linksys RTP300 | User Guide - Page 16
    router and PSTN connectivity. 8 Voice adapter with support for up to eight FXS devices. Supports SIP Trunking for inbound call routing to trunk groups. 2 IP router with two FXS ports. Provides ATA device functionality. 2 Wireless-G IP router with two FXS ports. Provides ATA device
  • Linksys RTP300 | User Guide - Page 17
    Telephone Adapters Comparison of ATA Devices Figure 1 illustrates how the different Linksys ATA devices provide voice connectivity in a VoIP network. Ethernet/Wireless LAN Fax (up to 4 SPA8000) Analog phone (up to 8 with SPA8000) WRP400, RTP300, WRTP54G, and SPA2102 PSTN Broadband router DSL
  • Linksys RTP300 | User Guide - Page 18
    the Linksys ATA device using Network Address Translation (NAT) and Port Address Translation (PAT). The packet is then routed back to the internal network on the Linksys ATA device by the local router or the ISP router. Problems can occur with calls between phones connected to the Linksys ATA device
  • Linksys RTP300 | User Guide - Page 19
    IVR (Line 1 or Line 2) Line 1 Line 2 Ethernet port LAN port IP Router (with hairpinning) or Broadband modem ISP LAN WAN Internet IP ITSP 187257 SPA2102 Administration PC By default, the device attached to the LAN port is assigned the network address 192.168.0.0 with a subnet mask of 255
  • Linksys RTP300 | User Guide - Page 20
    Line 1 or Line 2) PSTN Line 1 PSTN Line 1 Ethernet port IP Router (with hairpinning) or Broadband modem ISP LAN WAN LAN port Internet IP ITSP 187259 SPA3102 Administration PC By default, the device on the LAN port is assigned the network address 192.168.0.0 with a subnet mask of 255.255
  • Linksys RTP300 | User Guide - Page 21
    Line 1 NAT/PAT Internal DHCP Line 2 server Ethernet port Line 3 Line 4 AUX port IP Router (with hairpinning) or Broadband modem ISP LAN WAN Administration PC Internet IP ITSP Line 5 Line 6 Line 7 Line 8 187256 By default, the device on the AUX port is assigned the network address 192
  • Linksys RTP300 | User Guide - Page 22
    can initiate a three-way conference with both call legs using G.723.1. Note: The WRP400 device does not support the G.723.1 audio codec. NOTE: When no static payload value is assigned per RFC 1890, the Linksys ATA device can support dynamic payloads for G.726. Linksys ATA Administration Guide 22
  • Linksys RTP300 | User Guide - Page 23
    SIP proxy servers (via DNS SRV) so that service disruption should be nearly eliminated. A relatively simple way to support proxy redundancy is to configure your DNS server with a list of SIP proxy addresses. The Linksys ATA device can be instructed to contact a SIP proxy server in a domain named
  • Linksys RTP300 | User Guide - Page 24
    Introducing Linksys Analog Telephone Adapters ATA Software Features Feature International Caller ID Delivery Secure Calls Adjustable Audio Frames Per Packet DTMF Call Progress Tone Generation Call Progress Tone Pass Through Echo Cancellation Description In addition to support of the Bellcore (FSK)
  • Linksys RTP300 | User Guide - Page 25
    Introducing Linksys Analog Telephone Adapters ATA Software Features Feature Signaling Hook Flash Event Configurable Dial Plan with Interdigit Timers Polarity Control Calling Party Control Report Generation and Event Logging Syslog and Debug Server Records Description The Linksys ATA device can
  • Linksys RTP300 | User Guide - Page 26
    ports. With TCP, new ports do not need to be opened or packets dropped, because TCP is already in use for basic activities such as Internet browsing or e-commerce. SIP over TCP is configured in the Line tabs. See "Linksys ATA Voice Field Reference," on page 94. Linksys SPA2102 and SPA3102 devices
  • Linksys RTP300 | User Guide - Page 27
    to be operating correctly. If it returns a different address, the ATA device changes its IP address to the new address provided by the DHCP server. The Linksys ATA device then resets, and once again sends a SIP register request for the DHCP server to accept. Linksys ATA Administration Guide 27
  • Linksys RTP300 | User Guide - Page 28
    Proxy (IP address or name) - Account information and Password • Computer with Microsoft Windows XP or Windows Vista (for system configuration) • Analog phones • UPS (uninterruptible Power Source) recommended for devices such as the Integrated Access Device, network switch, router, and PoE switch to
  • Linksys RTP300 | User Guide - Page 29
    Basic Administration and Configuration of Your Linksys ATA Downloading Firmware Downloading Firmware Always download and install the latest firmware for your Linksys ATA device before doing any configurations. 1. Direct your browser to the following URL: http://www.linksys.com 2. In the Search box
  • Linksys RTP300 | User Guide - Page 30
    connected to the Ethernet port of the Linksys ATA device, the default IP address is 192.168.0.1. 3. Use the administration computer to install the latest firmware: a. Extract the Zip file, and then run the executable file to upgrade the firmware. b. When the Firmware Upgrade Warning window appears
  • Linksys RTP300 | User Guide - Page 31
    of your Linksys ATA device, you will use the administration web server to finish your configuration. Linksys ATA devices support two levels of administration privileges: Administrator and User. Both privileges can be password protected. NOTE: By default, there are no passwords assigned for
  • Linksys RTP300 | User Guide - Page 32
    Guide. 3. Direct the browser to the IP address of the ATA device. 4. The Router > Status page appears. By default, the page is in Basic User mode. Log on to the administrator view by clicking Admin Login, near the top right corner of the page. Then click Advanced. NOTE: By default, no password
  • Linksys RTP300 | User Guide - Page 33
    drop-down menu. This is the correct setting for most DSL users. b. Enter the values provided by the ITSP in the following fields: - PPPoE Login Name - PPPoE Login Password - PPPoE Service Name 4. Click Submit All Changes. The Linksys ATA device reboots. 5. To verify your progress, click the Router
  • Linksys RTP300 | User Guide - Page 34
    page is No, you cannot upgrade the ATA device even if the web page indicates otherwise. The syntax of the Upgrade URL is as follows: http://spa-ip-addr/admin/upgrade?[protocol://][server-name[:port]][/firmware-pathname] Both HTTP and TFTP are supported for the upgrade operation. If no protocol is
  • Linksys RTP300 | User Guide - Page 35
    Basic Administration and Configuration of Your Linksys ATA Provisioning Your Linksys ATA Device If no port specified, the default port of the protocol is used. (69 for TFTP or 80 for HTTP) The firmware-pathname is typically the file name of the binary located in a directory on the TFTP or HTTP
  • Linksys RTP300 | User Guide - Page 36
    the profile specifically for the target ATA device, without requiring an explicit key exchange. Remote firmware upgrade is achieved via TFTP or HTTP (firmware upgrades using HTTPS are not supported). Remote upgrades are controlled by configuring the desired firmware image URL into the ATA device via
  • Linksys RTP300 | User Guide - Page 37
    and Configuration of Your Linksys ATA Provisioning Your Linksys ATA Device The names of parameters in XML profiles can generally be inferred from the ATA configuration Web example, the Line 1 Proxy is named Proxy[1] in source text profiles for input to the SPC. Linksys ATA Administration Guide 37
  • Linksys RTP300 | User Guide - Page 38
    properly supports voice services. • "Network Address Translation (NAT) and Voice over IP (VoIP)," on page 38 • "Firewalls and SIP," on page 42 • "Configuring SIP Timer Values," on page 43 Network Address Translation (NAT) and Voice over IP (VoIP) NAT is a function that allows multiple devices to
  • Linksys RTP300 | User Guide - Page 39
    public) IP address that is static. • The NAT mechanism used in the router must be symmetric. See "Determining Whether the Router Uses Symmetric or Asymmetric NAT," on page 41. • The LAN switch must be configured to enable Spanning Tree Protocol and Port Fast on the ports to which the SPA devices are
  • Linksys RTP300 | User Guide - Page 40
    ," on page 41. • You must have a computer running STUN server software. • The LAN switch must be configured to enable Spanning Tree Protocol and Port Fast on the ports to which the SPA devices are connected. NOTE: Use NAT mapping only if the ITSP network does not provide a Session Border Controller
  • Linksys RTP300 | User Guide - Page 41
    : Your ITSP may require the SPA device to send NAT keep alive messages to keep the NAT ports open permanently. Check with your ITSP to determine the requirements. 6. Click Submit All Changes. NOTE: You also need to configure the firewall settings on your router to allow SIP traffic. See "Firewalls
  • Linksys RTP300 | User Guide - Page 42
    In the Debug Server field, enter the IP address of your syslog server. NOTE: This address and port number must be reachable from the SPA9000. c. From the Debug level drop-down list, choose 3. 4. To collect information about the type of NAT your router is using, complete the following tasks: a. Click
  • Linksys RTP300 | User Guide - Page 43
    may need to enter a longer SIP T1 retry value. To view the default settings or to make changes, open the Voice > SIP page, and scroll down to the SIP Timer Values section. For field descriptions, see "SIP Timer Values (sec) section," on page 103 of Appendix B. Linksys ATA Administration Guide 43
  • Linksys RTP300 | User Guide - Page 44
    page 49 • "Secure Call Implementation," on page 57 • "SIP Trunking and Hunt Groups on the SPA8000," on page 61 Supported Codecs The following list shows the current supported codecs for each Linksys ATA device. If you need to change the G711u codec which is configured by default, set your preferred
  • Linksys RTP300 | User Guide - Page 45
    The SPA2102 and SPA3102 support a single connection, while the SPA8000 supports one connection for each pair of ports (1/2, 3/4, 5/6, and 7/8) for a maximum of four connections. To optimize fax completion rates, complete the following steps: 1. Upgrade the Linksys ATA firmware to the latest version
  • Linksys RTP300 | User Guide - Page 46
    configuration file to Technical Support. 6. Enable and capture the debug log. For instructions, refer to Appendix D, "Troubleshooting.". NOTE: You may also capture data using a sniffer trace. 7. Identify the type of fax machine connected to the Linksys ATA device. Linksys ATA Administration Guide
  • Linksys RTP300 | User Guide - Page 47
    Configuring Voice Services Managing Caller ID Service 8. Contact technical support. If you are an end user of Linksys VoIP products, contact the reseller or Internet telephony service provider (ITSP) that supplied the equipment. If you are an authorized Linksys Voice System partner, contact Linksys
  • Linksys RTP300 | User Guide - Page 48
    the caller may think the call has been disconnected because of the "dead silence" periods created by the VAD and Silence Suppression feature. Silence suppression is configured in the Line and PSTN Line tabs. See "Linksys ATA Routing Field Reference," on page 86. Linksys ATA Administration Guide 48
  • Linksys RTP300 | User Guide - Page 49
    to block certain types of calls such as long distance or international. This section includes information that you need to understand dial plans, as well as procedures for configuring your own dial plans. . Enter x to represent any character on the phone keypad. Linksys ATA Administration Guide 49
  • Linksys RTP300 | User Guide - Page 50
    ! The system rejects any 11-digit sequence that begins with 1900. Enter an asterisk to allow the user to enter a 2-digit star code. Enter S0 to reduce the short inter-digit timer to 0 seconds, or enter L0 to reduce the long inter-digit timer to 0 seconds. Linksys ATA Administration Guide 50
  • Linksys RTP300 | User Guide - Page 51
    xxxxxxx This is example is useful where a local area code is required by the carrier but the majority of calls go to one area code. After the user presses 8, an external dial tone sounds. The user can enter any 1 and is followed by a digit 2 through 9. Linksys ATA Administration Guide 51
  • Linksys RTP300 | User Guide - Page 52
    valid. When a terminating event occurs, the SPA9000 either accepts the user-dialed sequence and initiates a call, or else rejects the sequence as invalid. The user hears the reorder (fast busy) tone if sequence is blocked by the dial plan, the number is rejected. Linksys ATA Administration Guide 52
  • Linksys RTP300 | User Guide - Page 53
    null entry is evaluated. Unless you have a special dial plan string to allow a null entry, the call is rejected. The default value is 5. Syntax for the Dial Plan Timer SYNTAX: (Ps | dial plan ) • s: timer, you allow more time for users to enter the digits. Linksys ATA Administration Guide 53
  • Linksys RTP300 | User Guide - Page 54
    of a dial plan. Alternatively, you can modify the Control Timer that controls the default interdigit timers for all calls. See "Resetting the Control Timers," on page 56. Syntax for the Interdigit Long Timer SYNTAX: and other printed materials while dialing. Linksys ATA Administration Guide 54
  • Linksys RTP300 | User Guide - Page 55
    If it is valid, the call proceeds. If it is invalid, the call is rejected. The default value is 3 seconds. Syntax Admin access with Advanced settings. 2. Click Voice tab > Line N, where N represents the line interface number. 3. Scroll down to the Dial Plan section. Linksys ATA Administration Guide
  • Linksys RTP300 | User Guide - Page 56
    Configuring Dial Plans 4. Enter the digit sequences in the Dial Plan field. For more information, see "About Dial Plans," on page 49. 5. Click Submit All Changes. Resetting the Control Timers You can use the following procedure to reset the default timer settings for all calls. NOTE: If you need to
  • Linksys RTP300 | User Guide - Page 57
    . The ATA device will not switch to secure mode if the CID of the called party from its MiniCertificate does not agree with the user-id used in making the outbound call. The ATA device performs this check after receiving the Mini-Certificate of the called party Linksys ATA Administration Guide 57
  • Linksys RTP300 | User Guide - Page 58
    call service with an MC and the corresponding 512-bit private key. The MC is signed with a 1024-bit private key of the service provider, which acts as the CA of the MC. The 1024-bit public key of the CA signing the MC must also be provisioned for each subscriber. Linksys ATA Administration Guide
  • Linksys RTP300 | User Guide - Page 59
    user-id used in the INVITE when making the call, such as "14083331234". The maximum length is 16 characters. • expire-date is the expiration date of the MC, such as "00:00:00 1/1/34" (34=2034). Internally the date is encoded as a fixed 12B string: 000000010134 Linksys ATA Administration Guide 59
  • Linksys RTP300 | User Guide - Page 60
    Secure Call Implementation The tool generates the Mini Certificate and SRTP Private Key parameters that can be provisioned. For example: gen_mc ca_key "Joe Private Key> b/DWc96X4YQraCnYzl5en1CIUhVQQqrvcr6Qd/8R52IEvJjOw/ e+Klm4XiiFEPaKmU8UbooxKG36SEdKusp0AQ== Linksys ATA Administration Guide 60
  • Linksys RTP300 | User Guide - Page 61
    SIP Trunking and Hunt Groups on the SPA8000 The SPA8000 supports SIP Trunking, which allows you to connect a traditional PBX to VoIP services. In this configuration, calls go through the ITSP rather than the PSTN, yet the call routing functionality is similar to that of traditional PSTN lines
  • Linksys RTP300 | User Guide - Page 62
    Access Device The SPA8000 offers four trunk groups, numbered T1, T2, T3, and T4. A SIP-based voice service with an ITSP can be configured on each trunk group with a distinct phone number. Each of the eight SPA8000 lines can be configured either as a standalone line, as in a classic ATA FXS port, or
  • Linksys RTP300 | User Guide - Page 63
    . The Internal Proxy Server handles all SIP signalling between both ends of the call, from call establishment to termination. • RTP Path: Whether the line is standalone or each Trunk Group can be configured with a different ITSP (with some limitations applied). Linksys ATA Administration Guide 63
  • Linksys RTP300 | User Guide - Page 64
    to the FXS port using the configured Caller ID method (FSK, DTMF, etc.). The PBX must be able to detect Caller ID signal in order for the proper Caller ID to show. 5. If the call is picked up UA and the ITSP equipment start exchanging RTP packets afterwards. Linksys ATA Administration Guide 64
  • Linksys RTP300 | User Guide - Page 65
    trunk group for this Contact List. • You can instruct the SPA8000 to hunt only the phones that are call is rejected or is forwarded to the specified call forward number (see below). - If max is greater than interval, it represents the total time in seconds to hunt. Linksys ATA Administration Guide
  • Linksys RTP300 | User Guide - Page 66
    to place the call to the ITSP if there is available capacity on the trunk. If there is no call capacity left on the trunk, the internal Proxy will reject the INVITE from the Line UA, which in turn terminates the call and plays reorder tone out to the FXS port. Linksys ATA Administration Guide 66
  • Linksys RTP300 | User Guide - Page 67
    , specify the call capacity, and configure the Contact List configuration page, choose a trunk number or choose none for a standalone line (the default setting). c. Repeat this step for each line that you want to add to a trunk group. Voice > Ln > Trunk Group field Linksys ATA Administration Guide
  • Linksys RTP300 | User Guide - Page 68
    : http:// spa8000-ip-addr/status. This page is available with the User Login orthe Admin Login. Trunk Status page The Trunk Status page shows all calls that are currently : • External: The called number • Station: The SPA8000 line that is in use for this call Linksys ATA Administration Guide 68
  • Linksys RTP300 | User Guide - Page 69
    only, not at the trunk level. Via the PBX, the phone user can trigger/control supplementary service and settings by signaling to the line port or configuring the line parameters. For more information, refer to the Appendix B, "Linksys ATA Voice Field Reference." Linksys ATA Administration Guide 69
  • Linksys RTP300 | User Guide - Page 70
    2. Start Internet Explorer, and then enter the IP address of the telephone. The Telephone Configuration page appears in a separate browser window. 3. Click Admin Login, and then click Advanced. 4. Click the Ext 1 tab. 5. Scroll down to the Call Feature Settings section. 6. Enter the following value
  • Linksys RTP300 | User Guide - Page 71
    Audio Server The Streaming Audio Server (SAS) feature lets you attach an audio source to an FXS port and use it as a streaming audio source device. If the unit has multiple FXS ports, either or both of the associated lines can be configured as an SAS server. Linksys ATA Administration Guide 71
  • Linksys RTP300 | User Guide - Page 72
    an SAS with an external music source. 1. Connect an RJ-11 adapter between the music source (a CD player or iPod, for example) and an FXS port. 2. Start Internet Explorer, connect to the administration web server, and choose Admin access with Advanced settings. Linksys ATA Administration Guide 72
  • Linksys RTP300 | User Guide - Page 73
    click the hyperlink in the IP Address column. The Telephone Configuration page appears in a separate window. c. Click the Ext 1 tab. d. Scroll down to the Call Feature Settings section. e. In the MOH Server field, enter the extension number that you assigned to the FXS port for the streaming audio
  • Linksys RTP300 | User Guide - Page 74
    to obtain VoIP service Line 1 can be configured with a regular VoIP account and can be used in the same way as the Line 1 of any Linksys ATA device. With the SPA3102 and AG310 devices, a second VoIP account can be configured to support PSTN gateway calls exclusively. A different SIP port should be
  • Linksys RTP300 | User Guide - Page 75
    -Number> is the number dialed by the VoIP caller, and is a valid address of the SPA3102 or AG310 device, such as 10.0.0.100:5061. If the FXO port is currently in use (off-hook) or the PSTN line is being used by another extension, the Linksys ATA device replies to the INVITE with a 503
  • Linksys RTP300 | User Guide - Page 76
    PSTN as is. NOTE: If Authentication is disabled, a default dial plan is used for all unknown VoIP users. Two-Stage Dialing In two-stage dialing, the Linksys ATA device takes the FXO port off-hook but does not automatically dial any digits after accepting the call. To invoke two-stage dialing, the
  • Linksys RTP300 | User Guide - Page 77
    , the Linksys ATA device takes the FXO port on hook and sends a BYE request to end the VoIP call leg. On the other hand, when the Linksys ATA device receives a SIP BYE from the VoIP during a call, it takes the FXO port on hook to end the PSTN call leg. In addition, the Linksys ATA device can also
  • Linksys RTP300 | User Guide - Page 78
    to any IP address entered by the user. The Linksys ATA device allows flexible call routing with four sets of gateway parameters and configurable dial plans. The following table lists VoIP outbound call routing parameters. Parameter Gateway 1 GW1 Nat Mapping Enable GW1 User ID GW2 Password Web Page
  • Linksys RTP300 | User Guide - Page 79
    given port, user-id, and password, and no pstn.Linksys.com:5061, and with user-id = "Alex Bell" and pwd = bell_pwd, and disable NAT mapping You can set up multiple PSTN gateways at different locations and configure Line 1 to use a different gateway when dialing specific numbers. Configuring VoIP
  • Linksys RTP300 | User Guide - Page 80
    Configuring the PSTN (FXO) Gateway Sharing One VoIP Account Between the FXS and PSTN Lines Sharing One VoIP Account Between the FXS and PSTN Lines Both the FXS (Line 1) and FXO (PSTN Line) can to receive incoming calls for a single VoIP account if they are different ports. Consider the following: •
  • Linksys RTP300 | User Guide - Page 81
    the source IP and port of the inbound RTP packets. This facilitates NAT traversal. The following table lists symmetric RTP parameters. Parameter Symmetric RTP Symmetric RTP Web Page Description Values Line 1 Enable symmetric RTP operation. If enabled, the Linksys ATA device sends RTP packets
  • Linksys RTP300 | User Guide - Page 82
    and processes the number using the dial plan. The Linksys ATA device plays the Outside Dial Tone to prompt the VoIP caller to enter the PSTN number. This tone should be specified to sound different from the PSTN dial tone. Call Scenarios This section describes some typical scenarios where the
  • Linksys RTP300 | User Guide - Page 83
    the source IP address of the INVITE request is in the VoIP Access List . Using HTTP Digest Authentication The same scenario can be implemented with HTTP digest authentication when the calling device supports the configuration of a auth-ID and password to access the Linksys ATA device PSTN gateway
  • Linksys RTP300 | User Guide - Page 84
    Line A comma-separated list of IP address templates, such that callers with a source IP address matching any of the templates are accepted for PSTN gateway service without further authentication. For example: 192.168.*.*, 66.43.12.1??. The default is blank. Linksys ATA Administration Guide 84
  • Linksys RTP300 | User Guide - Page 85
    set to @gw0>. This is the same as in the previous examples, except that the Linksys ATA device automatically dials the given target number on the PSTN line right after it answers the VoIP call leg. This is a special case of onestage dialing where the target number is specified in the
  • Linksys RTP300 | User Guide - Page 86
    Information section Product Name Serial Number Software Version Hardware Version MAC Address Model number of the ATA device. Serial number of the ATA device. Version number of the ATA software. Version number of the ATA hardware. MAC address of the ATA device. Linksys ATA Administration Guide 86
  • Linksys RTP300 | User Guide - Page 87
    type: DHCP or Static IP. The current IP address assigned to the ATA device. The current IP address assigned to the ATA device. The network domain name of the ATA device. The network mask assigned to the ATA device. The default router assigned to the ATA device. The primary DNS server assigned
  • Linksys RTP300 | User Guide - Page 88
    The NetMask used by ATA device when DHCP is disabled. The default is 255.255.255.0. The default gateway used by ATA device when DHCP is disabled. The default is 0.0.0.0. Router tab > WAN Setup page > PPPoE Settings section PPPoE Login Name PPPoE Login Password PPPoE Service Name The account name
  • Linksys RTP300 | User Guide - Page 89
    with your ISP to the router with the MAC Address Clone feature. Enable MAC Clone Service Cloned MAC Address To use MAC Address cloning, select Yes. Default is No. Use when your ISP requires a certain MAC address. It's usually the address for your PC. Linksys ATA Administration Guide 89
  • Linksys RTP300 | User Guide - Page 90
    that is not directly connected to the ATA device. Options are Yes or No. The default value is Yes. The port that is used for WAN access to the ATA device. The default value is 80. Router tab > WAN Setup page > QOS Settings section Use Quality of Service (QoS) to assign different priority levels to
  • Linksys RTP300 | User Guide - Page 91
    not give IP addresses. Router tab > LAN Setup page > LAN Networking Settings section Use these network settings when using NAT. LAN IP Address LAN Subnet Mask Enable DHCP Server DHCP Lease Time DHCP Client Starting IP Address Number of Client IP Addresses IP address of the Linksys ATA device on
  • Linksys RTP300 | User Guide - Page 92
    port is forwarded must have its DHCP client function disabled and should have a new static IP address assigned to it because its address may change when using the DHCP function. To expose one PC, select Yes. The default is No. Specify the host computer's IP address. Linksys ATA Administration Guide
  • Linksys RTP300 | User Guide - Page 93
    as a reserve port and that is not used for NAT translation. That is, if there is a conflict - if port forwarding is set on the same port - then the port forwarding is cancelled. Default is 50000. Total number of ports reserved. Options are: 256, 512, and 1024. Linksys ATA Administration Guide 93
  • Linksys RTP300 | User Guide - Page 94
    configure under the Voice tab in the administration web server pages. NOTE: For information about the Voice > Provisioning tab, see the Linksys SPA Provisioning Guide applicable to your ATA device or your setup. Info page You can use the Info page to view information about the ATA device. With some
  • Linksys RTP300 | User Guide - Page 95
    Customization Description Model number/name. Serial number. Software version number. Hardware version number. MAC address. Status of the client certificate, which can indicate if the ATA device has been authorized by your ITSP. For a Remote Configuration (RC) unit, this field indicates whether the
  • Linksys RTP300 | User Guide - Page 96
    or power cycle. Call Back Active Indicates whether a call back request is in progress. Options are either Yes or No. Last Called Number The last number called from the FXO Line. Last Caller Number Number of the last caller. Mapped SIP Port Port number of the SIP port mapped by NAT. Call
  • Linksys RTP300 | User Guide - Page 97
    . Displays the current IP address assigned to the ATA device. Displays the current IP address assigned to the ATA device. Displays the network domain name of the ATA device. Displays the network mask assigned to the ATA device. Displays the default router assigned to the ATA device. Displays the
  • Linksys RTP300 | User Guide - Page 98
    number of the SIP port mapped by NAT. May take one of the following values: • PSTN Gateway Call = VoIP-To-PSTN Call • VoIP Gateway Call = PSTN-To-VoIP Call • PSTN To Line 1 = PSTN call ring through and answered by Line 1 • Line 1 Forward to PSTN Gateway = VoIP calls Line 1 then forwarded to PSTN GW
  • Linksys RTP300 | User Guide - Page 99
    signal. This parameter is stored in long term memory and survives after reboot or power cycle. Port number of the SIP port mapped by NAT. Voice tab > System page You can use the System page to configure your system and network connections. With some variations, depending on the model, this page
  • Linksys RTP300 | User Guide - Page 100
    Web Server Web Server Port Enable Web Admin Access Admin Password User Password Description This feature is used when implementing software customization. Enable/disable web server of the ATA device. This feature should only be used on firmware version 1.0.9 or later. The default is yes. This field
  • Linksys RTP300 | User Guide - Page 101
    selecting the DNS server. The options are Manual (enter the IP address of the DNS server manually; that is do not look at the DHCP-supplied DNS table), Manual/DHCP, and DHCP/Manual. Do parallel or sequential DNS Query. With parallel DNS query mode, the ATA device sends the same request to all the
  • Linksys RTP300 | User Guide - Page 102
    ATA device does not include this header). If empty, the header is not included. MIME Type used in a SIP INFO message to signal a DTMF event. The default is application/dtmf-relay. MIME Type used in a SIP INFO message to signal a hook flash event. The default is application/hook-flash. Linksys ATA
  • Linksys RTP300 | User Guide - Page 103
    Port Max Lets you remove the last registration before registering a new one if the value is different. Select yes or no from the drop-down menu. The default is no. Lets you use compact SIP headers in outbound SIP messages. Select yes or no from the drop-down menu. If set to yes, the ATA device
  • Linksys RTP300 | User Guide - Page 104
    used. The default is 7200. Reg Retry Intvl Interval to wait before the ATA device retries registration after failing during the last registration. The default is 30. adjusted delay value. The default value is 0, which disables the exponential back-off feature. Linksys ATA Administration Guide 104
  • Linksys RTP300 | User Guide - Page 105
    of 0.01 seconds. The default is 0.030. Number of successive ICMP errors allowed when transmitting RTP packets to the peer before the ATA device terminates the call. If value is set to 0, the ATA device ignores the limit on ICMP errors. The default is 0. Linksys ATA Administration Guide 105
  • Linksys RTP300 | User Guide - Page 106
    checksum for SIP messages. Otherwise, select no. The default is no. Determines whether the ATA device includes the P-RTP-Stat header or response to a BYE message. The header contains the RTP statistics of the current call. Select yes or no from the drop-down menu. The format of the PRTP-Stat header
  • Linksys RTP300 | User Guide - Page 107
    is ignored. Select yes or no from the drop-down menu. The default is no. Inserts the received parameter into the VIA header of SIP responses if the received-from IP and VIA sent-by IP values differ. Select yes or no from the drop-down menu. The default is no. Linksys ATA Administration Guide 107
  • Linksys RTP300 | User Guide - Page 108
    , the ATA device assumes this IP address when generating SIP messages and SDP (if NAT Mapping is enabled for that line). However, the results of STUN and VIA received parameter processing, if available, supersede this statically configured value. The default is 0.0.0.0. External port mapping number
  • Linksys RTP300 | User Guide - Page 109
    List field. The following options are available: • onhook only: An incoming call is directed to a specified trunk line only if the call state is onhook. • any state: An incoming call is directed to any specified trunk line without regard to the call state. Linksys ATA Administration Guide 109
  • Linksys RTP300 | User Guide - Page 110
    19,620@-19;10(.5/.5/1+2). Played when an outbound call has failed or after the far end hangs up during an established call. Reorder Tone is played automatically when Dial Tone or any of its alternatives times out. The default is 480@-19,620@-19;10(.25/.25/1+2). Linksys ATA Administration Guide 110
  • Linksys RTP300 | User Guide - Page 111
    a call has been successfully switched to secure mode. It should be played only for a short while (less than 30 seconds) and at a reduced level (less than -19 dBm) so it does not interfere with the conversation. The default is 397@-19,507@-19;15(0/2/0,.2/.1/1,.1/2.1/2). Linksys ATA Administration
  • Linksys RTP300 | User Guide - Page 112
    script for distinctive ring 7. The default is 60(.4/.2,.4/.2,.4/4). Cadence script for distinctive ring 8. The default is 60(0.25/9.75). Cadence script for distinctive ring 9. This field is for the SPA2102 and SPA8000 only. The default is 60(.4/.2,.4/2). Linksys ATA Administration Guide 112
  • Linksys RTP300 | User Guide - Page 113
    The default is Bellcore-r3. Name in an INVITE's Alert-Info Header to pick distinctive ring/CWT 4 for the inbound call. The default is Bellcore-r4. Name in an INVITE's Alert-Info Header to pick distinctive ring/CWT 5 for the inbound call. The default is Bellcore-r5. Linksys ATA Administration Guide
  • Linksys RTP300 | User Guide - Page 114
    device will tear down the current inbound call. It does not apply to outbound calls. Range: 0-255 seconds. The default is 0. Delay after far end hangs up before reorder tone is played. 0 = plays immediately, inf = never plays. Range: 0-255 seconds. The default is 5. Linksys ATA Administration Guide
  • Linksys RTP300 | User Guide - Page 115
    this time, the ATA device still considers the call as failed and keeps on retrying. The default is 0.5. Interval between VMWI refresh to the CPE. The default is 0.5. Long timeout to 1.000 second. Resolution is 0.001 second. The default is 0 (CPC disabled). Linksys ATA Administration Guide 115
  • Linksys RTP300 | User Guide - Page 116
    Cfwd Last Deact Code Cancels call forwarding of the last inbound or outbound calls. The default is *83. Block Last Act Code Blocks the last inbound call. The default is *60. Block Last Deact Code Cancels blocking of the last inbound call. The default is *80. Linksys ATA Administration Guide 116
  • Linksys RTP300 | User Guide - Page 117
    . The default is *45. Dist Ring Act Code Enables the distinctive ringing feature. The default is *26 Dist Ring Deact Code Disables the distinctive ringing feature. The default is *46. Speed Dial Act Code Assigns a speed dial number. The default is *74. Linksys ATA Administration Guide 117
  • Linksys RTP300 | User Guide - Page 118
    server to perform further processing, such as call park. The *codes should not conflict with any of the other vertical service codes internally processed by the ATA device. You can empty the corresponding *code that you do not want to ATA device to process. Linksys ATA Administration Guide 118
  • Linksys RTP300 | User Guide - Page 119
    are place, x is any digit not used above If no tone parameter is specified, the ATA device plays Prompt tone by default. If the *code is not to be followed by a phone number, such as *73 to cancel call forwarding, do not include it in this parameter. In that case, simple add that *code in
  • Linksys RTP300 | User Guide - Page 120
    only codec that can be used for the associated call. The default is *0272640. Makes this codec the preferred codec for the associated call. The default is *01729. Makes this codec the only codec that can be used for the associated call. The default is *02729. Linksys ATA Administration Guide 120
  • Linksys RTP300 | User Guide - Page 121
    Description Set Local Date (mm/dd) Sets the local date (mm stands for months and dd stands for days). The ..., GMT+13:00. The default is GMT-08:00. FXS Port Impedance Sets the electrical impedance of the FXS port. Choices are 600, 900, Default is Yes (on). Linksys ATA Administration Guide 121
  • Linksys RTP300 | User Guide - Page 122
    The ATA device supports bell 202 and v.23 standards for caller ID generation. Select the FSK standard you want to use, bell 202 or v.23. The default is bell 202. This field is not found in the PAP2T. The choices are from 1 to 8. This field is only found in the PAP2T. The default is 3. Linksys ATA
  • Linksys RTP300 | User Guide - Page 123
    Enable or disable more echo suppresion. The default is no. This field is not found in the PAP2T. Voice tab > Line page Depending on the ATA device, there may be one or more Line pages (L1, L2, and so on). You can use the Line page to configure the lines for voice service. With some variations
  • Linksys RTP300 | User Guide - Page 124
    SAS client will stream audio to the given address. Special case: If the value is $IP, then the SAS line's own IP address is used in the c = line and a=sendrecv. In that case the SAS client will stream RTP packets to the SAS line. The default value is empty. Linksys ATA Administration Guide 124
  • Linksys RTP300 | User Guide - Page 125
    > Line page > NAT Settings section Field NAT Mapping Enable NAT Keep Alive Enable NAT Keep Alive Msg NAT Keep Alive Dest Description To use externally mapped IP addresses and SIP/RTP ports in SIP messages, select yes. Otherwise, select no. The default is no. To send the configured NAT keep alive
  • Linksys RTP300 | User Guide - Page 126
    ATA device adds a GUID header in the SIP request. The GUID is generated the first time the unit boots up and stays with the unit through rebooting and even factory reset. This feature was requested by Bell Canada (Nortel) to limit the registration of SIP accounts. The default is yes. Linksys ATA
  • Linksys RTP300 | User Guide - Page 127
    SIP Ports originated from an untrusted IP address. A source IP address is untrusted if it does not match any of the IP addresses resolved from the configured Proxy (or Outbound Proxy if Use Outbound Proxy is yes). The default is no. Controls when the ATA device sends BYE to terminate stale call legs
  • Linksys RTP300 | User Guide - Page 128
    SPA2102 only. Default is yes. The IP address of the local address enclosed in the FROM of the SIP message. This field is found on the SPA2102 only. Default is no. Voice tab > Line page > Call Feature Settings section Field Description Blind Attn-Xfer Enable Enables the ATA device to perform an
  • Linksys RTP300 | User Guide - Page 129
    normal first, and also inspect the port number based on 1st proxy's port on the list. The default is Normal. Enter the URL or IP address of the server. Expiry time to the voice mail server. The time to send another subscribe message to the voice mail server. Linksys ATA Administration Guide 129
  • Linksys RTP300 | User Guide - Page 130
    default is empty. Voice tab > Line page > Supplementary Service Subscription section The ATA device provides native support of a large set of enhanced or supplementary services. All of these services are optional. The parameters listed in the following table are used to enable or disable a specific
  • Linksys RTP300 | User Guide - Page 131
    (Blind) Call Transfer Service. The default is yes. Enable MWI Service. MWI is available only if a Voice Mail Service is set-up in the deployment. The default is yes. Enable VMWI Service (FSK). The default is yes. Enable Speed Dial Service. The default is yes. Linksys ATA Administration Guide 131
  • Linksys RTP300 | User Guide - Page 132
    will be routed to Gateway 1. Without the syntax, all calls are routed to the given proxy by default (except IP dialing). The default is blank. If enabled, the ATA device uses NAT mapping when contacting Gateway 1. The default is no. This value is the authentication user-id to be used by the
  • Linksys RTP300 | User Guide - Page 133
    VoIP Fallback to PSTN section (SPA3102/AG310) Field Auto PSTN Fallback Description If enabled, the ATA device automatically routes all calls to the PSTN gateway when the Line 1 proxy is down (registration failure or network link down). The default , FWD, ...) Linksys ATA Administration Guide 133
  • Linksys RTP300 | User Guide - Page 134
    patterns. If outbound call matches one of the pattern, SPA will disable hook flash event handling. The condition is restored to normal after the phone is onhook. Blank signifies no emergency number. Maximum number length is 63 characters. The default is blank. Linksys ATA Administration Guide 134
  • Linksys RTP300 | User Guide - Page 135
    Line page > FXS Port Polarity Configuration section Field Idle Polarity Description Polarity before a call is connected: Forward or Reverse. The default is Forward. Caller Conn Polarity Polarity after an outbound call is connected: Forward or Reverse. The default is Forward. Callee Conn Polarity
  • Linksys RTP300 | User Guide - Page 136
    ATA device adds a GUID header in the SIP request. The GUID is generated the first time the unit boots up and stays with the unit through rebooting and even factory reset. This feature was requested by Bell Canada (Nortel) to limit the registration of SIP accounts. The default is yes. Linksys ATA
  • Linksys RTP300 | User Guide - Page 137
    SIP Ports originated from an untrusted IP address. A source IP address is untrusted if it does not match any of the IP addresses resolved from the configured Proxy (or Outbound Proxy if Use Outbound Proxy is yes). The default is no. Controls when the ATA device sends BYE to terminate stale call legs
  • Linksys RTP300 | User Guide - Page 138
    ). If there is no answer within 12 seconds (12), the Trunk SUA chooses another line at random. If there is no answer after 1 round (1), the call is forwarded to forwarded to the specified number (cfwd=14089993326). Linksys ATA Administration Guide 138
  • Linksys RTP300 | User Guide - Page 139
    Group page > NAT Settings section Field NAT Mapping Enable NAT Keep Alive Enable NAT Keep Alive Msg NAT Keep Alive Dest Description To use externally mapped IP addresses and SIP/RTP ports in SIP messages, select yes. Otherwise, select no. The default is no. To send the configured NAT keep alive
  • Linksys RTP300 | User Guide - Page 140
    Proxy Use Outbound Proxy Outbound Proxy Use OB Proxy In Dialog Register Make Call Without Reg Register Expires Ans Call Without Reg Use DNS SRV DNS SRV Auto Prefix Proxy Fallback Intvl Description not attempt to fall back after a fail over). The default is 3600 Linksys ATA Administration Guide 140
  • Linksys RTP300 | User Guide - Page 141
    will contain proxies ranked by weight and priority. if Based on SRV port is configured the PAP2T does normal first, and also inspect the port number based on 1st proxy's port on the list. The default is Normal. Enter the URL or IP address of the server. Expiry time to the voice mail server. The time
  • Linksys RTP300 | User Guide - Page 142
    Line page > NAT Settings section Field NAT Mapping Enable NAT Keep Alive Enable NAT Keep Alive Msg NAT Keep Alive Dest Description To use externally mapped IP addresses and SIP/RTP ports in SIP messages, select yes. Otherwise, select no. The default is no. To send the configured NAT keep alive
  • Linksys RTP300 | User Guide - Page 143
    ATA device adds a GUID header in the SIP request. The GUID is generated the first time the unit boots up and stays with the unit through rebooting and even factory reset. This feature was requested by Bell Canada (Nortel) to limit the registration of SIP accounts. The default is yes. Linksys ATA
  • Linksys RTP300 | User Guide - Page 144
    to its SIP Ports originated from an untrusted IP address. A source IP address is untrusted if it does not match any of the IP addresses resolved from the configured Proxy (or Outbound Proxy if Use Outbound Proxy is yes). The default is no. Referor Bye Delay Controls when the ATA device sends BYE
  • Linksys RTP300 | User Guide - Page 145
    In Dialog Register Make Call Without Reg Register Expires Ans Call Without Reg Use DNS default is no. If enabled, the PAP2T will automatically prepend the Proxy or Outbound Proxy name with _sip._udp when performing a DNS SRV lookup on that name. The default is no. Linksys ATA Administration Guide
  • Linksys RTP300 | User Guide - Page 146
    for subsequent calls; the only choices are G711a and G711u. On the other hand, two G.723.1/G.726 resources are available per device. Therefore it is important to disable the use of G.729a in order to guarantee the support of two simultaneous G.723/G.726 codec. Linksys ATA Administration Guide 146
  • Linksys RTP300 | User Guide - Page 147
    . Otherwise, select no. The default is yes. G726-40 Enable To enable the use of the G726 codec at 40 kbps, select yes. Otherwise, select no. The default is yes. FAX Passthru Codec Select the codec for fax passthrough, G711u or G711a. The default is G711u. Linksys ATA Administration Guide 147
  • Linksys RTP300 | User Guide - Page 148
    , the SPA3102 sends RTP packets to the source address and port of the last received valid inbound RTP packet. If disabled (or before the first RTP packet arrives) the SPA3102 sends RTP to the destination as indicated in the inbound SDP. The default is yes. Linksys ATA Administration Guide 148
  • Linksys RTP300 | User Guide - Page 149
    7, 8} Authentication is skipped for Line 1 VoIP caller. The default is 1. Default VoIP Caller DP Index of the dial plan in the dial plan pool to be used when the VoIP Caller is not authenticated. Choose from {none, 1, 2, 3, 4, 5, 6, 7, 8}. The default is 1. Linksys ATA Administration Guide 149
  • Linksys RTP300 | User Guide - Page 150
    1. VoIP User 1/2/3/4/5/6/7/ The password to be used with VoIP User 1. The user assumes the identity of 8 Password VoIP User 1 must therefore compute the credentials using this password, or the INVITE will be challenged with a 401 response The default is blank. Linksys ATA Administration Guide
  • Linksys RTP300 | User Guide - Page 151
    Timeout Timeout to wait for the 1st or subsequent PIN digits from a VoIP caller. The range is 0-255. The default is 10. PSTN PIN Digit Timeout Timeout to wait for the 1st or subsequent PIN digits from a PSTN caller. The range is 0-255. The default is 10. Linksys ATA Administration Guide 151
  • Linksys RTP300 | User Guide - Page 152
    is blank, the default is used. PSTN Hook Flash Len The length of the hook flash in seconds. During a PSTN-to-VoIP gateway call, the Linksys ATA device processes the out-of-band hook flash signal sent from the VoIP peer through a hook-flash (momentary on-hook signal) on the FXO port. This allows
  • Linksys RTP300 | User Guide - Page 153
    Tone If enabled, SPA will disconnect both call legs when it detects the disconnect tone from the PSTN side during a gateway call. Disconnect tone is specified in the Disconnect Tone parameter, which depends on the region of the PSTN service. The default is yes. Linksys ATA Administration Guide 153
  • Linksys RTP300 | User Guide - Page 154
    PSTN silence (or inactivity) in seconds to trigger a gateway call disconnection if Detect Long Silence is yes. The default is 30. This parameter adjusts the sensitivity of PSTN silence (0.5/0.5/1)- Impedance: n/a Denmark-425@-10; 10(0.25/0.25/1)- Impedance: 600 Linksys ATA Administration Guide 154
  • Linksys RTP300 | User Guide - Page 155
    FXO Port Impedance Desired impedance of the FXO Port. Choose default is Less than 0.5ms. Current Limiting Enable Enable or disable current limiting. The default is no. Ring Frequency Min Minimum ring frequency to detect. The range is 5-100. The default is 10. Linksys ATA Administration Guide
  • Linksys RTP300 | User Guide - Page 156
    available to incoming VoIP callers). The default value is 40v. Voice tab > User page Depending on the model of ATA device, there may be one or more User pages. You can use this page to configure the user settings. This page includes the following sections: • "Call Forward Settings section" section
  • Linksys RTP300 | User Guide - Page 157
    Caller service. The default is blank. The Caller number that is actively forwarded to Cfwd Last Dest by using the Call Forward Last activation code The default is blank. Forward number for the Cfwd Last Caller parameter. Same as Cfwd All Dest. The default is blank. Linksys ATA Administration Guide
  • Linksys RTP300 | User Guide - Page 158
    by the ATA device. The user can also manually modify it to clear or set the flag. Setting this value to yes can activate stutter tone and VMWI signal. This parameter is stored in long term memory and will survive after reboot or power cycle. The default is no. Linksys ATA Administration Guide 158
  • Linksys RTP300 | User Guide - Page 159
    and the call must be picked up manually before loopback starts. The default is Automatic. Media Loopback Mode The loopback mode to assume locally when making call to request media loopback. Choices are: Source and Mirror. Default is Source. Note that if the Linksys ATA device answers the call, the
  • Linksys RTP300 | User Guide - Page 160
    or forwarded to a certain VoIP number. If the caller is blocked, the SPA will not auto-answers the call. Eight VoIP destinations to forward a PSTN caller matching the Cfwd Sel x Caller parameter. If this entry is blank, the PSTN caller is blocked for VoIP service. Linksys ATA Administration Guide
  • Linksys RTP300 | User Guide - Page 161
    section Field Default Ring Description The default ring to be used to ring through Line 1. Choose from {1,2,3,4,5,6,7,8,Follow Line 1}. If Follow Line 1 is selected, the ring to be used is determined by Line 1's distinctive ring settings. The default is 1. Linksys ATA Administration Guide 161
  • Linksys RTP300 | User Guide - Page 162
    XML profile by using the Linksys profile compiler tool (SPC). NOTE:For instructions about provisioning, see the Linksys SPA Provisioning Guide (available to partners through the Linksys Partner Connection in North America and through ). Feature/XML Tag Wireless QoS Internet Access Priority
  • Linksys RTP300 | User Guide - Page 163
    RULE> QOS_PRIORITY_RULE> category_num: QoS Category number; = 1,name= ap1, priority=3,port_range= 111;222; 0;333;444;1 1 (application), 2 (online game), 3 To configure a rule for an online game: (MAC address), 4 (Ethernet port) Format 1 (default game):
  • Linksys RTP300 | User Guide - Page 164
    Service Provider to lock SSID2; when enabled, user will not be able to configure SSID2 from the device GUI; 1 (enabled) or 0 (disabled) Wireless Security for wl_security_ To disable Wireless , WPA Enterprise, WPA2 Enterprise, or Disabled Linksys ATA Administration Guide 164
  • Linksys RTP300 | User Guide - Page 165
    To enable Wireless WEP 1 and specify the passphrase and keys: wl_security_ mode2= wep,wl_wep_bit=64,wl_ passphrase=test1, .111, address wl_radius_port=6666,wl_radius_key= wl_radius_port: RADIUS port number; 666 Linksys ATA Administration Guide 165
  • Linksys RTP300 | User Guide - Page 166
    of 4, the throughput is limited to 50Mbps. MPORTANT: It is highly recommended to keep the default switch rate settings. Default settings hae been tested to support the appropriate Quality of Service for the IPTV video transmission towards the et-top box, in addition to maintaining the appropriate
  • Linksys RTP300 | User Guide - Page 167
    IP address wan_netmask: WAN subnet mask wan_gateway: Gateway IP address To configure Password; enter from 1 to 63 ASCII characters Heartbeat for Telstra Cable Network To configure a Telstra Cable connection: Parameters wan_proto= hb_server_ip: Heartbeat server IP address To configure
  • Linksys RTP300 | User Guide - Page 168
    576 to 1500 enable=1,wan_mtu=888 NOTE: The default size depends on the Internet Connection Type: To enable MTU in Manual mode without DHCP or Static IP: 1500 PPPoE: 1492 specifying the MTU size 21 192.168.0.22 192.168.0.23 192.168.0.23 Linksys ATA Administration Guide 168
  • Linksys RTP300 | User Guide - Page 169
    on|off: 0n (Enabled or off (Disabled both|tcp|udp: Selected protocol; tcp, udp, or both external-port: The external port number internal-port: The internal port number ip: The IP address of the PC running the specific application. Linksys ATA Administration Guide 169
  • Linksys RTP300 | User Guide - Page 170
    >port_trigge To configure two port range triggers: r=name:on|off:trigger start:trigger port_ end:forward start:forward end port_trigger: Supports port range
  • Linksys RTP300 | User Guide - Page 171
    access to the administration web server. 8. Open the web browser on a networked computer. 9. Start Internet Explorer and enter the IP address of the ATA device. Q. I'm trying to access the Linksys ATA administration web server, but I do not see the login screen. Instead, I see a screen saying, "404
  • Linksys RTP300 | User Guide - Page 172
    from Linksys. This will reset the Admin account password to the default of blank. 3. Press 1 to confirm the operation. Press * to cancel the operation. 4. Login to the unit using the User or Admin account without a password and reconfigure the unit as necessary. Linksys ATA Administration Guide
  • Linksys RTP300 | User Guide - Page 173
    Q. My ATA device is behind a NAT device or firewall and I'm unable to make a call or I'm only receiving a one-way connection. What should I do? A: 1. Configure your router to port forward "TCP port 80" to the IP address currently being used by your Linksys ATA device. If you do this often, we
  • Linksys RTP300 | User Guide - Page 174
    Environmental Specifications PAP2T Device Dimensions 3.98" x 3.98" x 1.10" (101 x 101 x 28 mm) W x H x D Unit Weight 5.40 oz (153g) Power 100-240V 50-60Hz, AC Input Certification FCC (Part 15 Humidity 10% to 90% relative humidity, Non-Condensing PAP2T Linksys ATA Administration Guide 174
  • Linksys RTP300 | User Guide - Page 175
    % to 90% relative humidity, Non-Condensing SPA8000 Device Dimensions 6.69" x 1.54" x 8.66" (170 x 39 x 220 mm) Unit Weight 2.85 lbs (1.30kg) Power 100-240V 50-60Hz (26-34VA), AC Input Storage Humidity 10% to 90% relative humidity, Non-Condensing SPA3102 Linksys ATA Administration Guide 175
  • Linksys RTP300 | User Guide - Page 176
    RTP300 RTP300 Device Dimensions 6.69" x 6.69" x 1.22" (170 x 170 x 31 mm) Unit Weight 12.20 oz (.346 kg) Power Device Dimensions 5.51" x 5.51" x 1.06" (140 x 140 x 27 mm) Unit Weight 10.05 oz (285 g) Power External, Switching humidity, Non-Condensing Linksys ATA Administration Guide 176
  • Linksys RTP300 | User Guide - Page 177
    90% relative humidity, Non-Condensing AG310 Device Dimensions 6.69 " x 6.69" x 1.22" (170 x 170 x 31 mm) Unit Weight 14.39 oz (.41 kg) Power 12V DC, 1.25A Certification FCC (Part -Condensing Storage Humidity 5% to 90% relative humidity, Non-Condensing Linksys ATA Administration Guide 177
  • Linksys RTP300 | User Guide - Page 178
    , defaced, or removed, or (g) the product is supplied or licensed for beta, evaluation, testing or demonstration purposes for which Linksys does not charge a purchase price or license fee. ALL SOFTWARE PROVIDED BY LINKSYS WITH THE PRODUCT, WHETHER FACTORY LOADED ON THE PRODUCT OR CONTAINED ON MEDIA
  • Linksys RTP300 | User Guide - Page 179
    (VAR) from whom you purchased the product or Linksys Technical Support for instructions on how to obtain warranty service. The telephone number for Linksys Technical Support in your area can be found in the product User Guide and at www.linksys.com. Have your product serial number and proof of
  • Linksys RTP300 | User Guide - Page 180
    This device must accept any interference, including interference that may cause undesired operation of the device. Règlement d'Industry Canada Cet appareil est conforme à la norme NMB003 d'Industrie Canada. Le fonctionnement est soumis aux conditions suivantes : Linksys ATA Administration Guide
  • Linksys RTP300 | User Guide - Page 181
    • EN55022 Emission • EN55024 Immunity The following acknowledgements pertain to this software license. User Information for Consumer Products Covered by EU Directive 2002 local authorities, waste disposal service, or the shop where you purchased the product. Linksys ATA Administration Guide 181
  • Linksys RTP300 | User Guide - Page 182
    ötigen, wenden Sie sich bitte an die örtlichen Behörden oder städtischen Entsorgungsdienste oder an den Händler, bei dem Sie das Produkt erworben haben. Linksys ATA Administration Guide 182
  • Linksys RTP300 | User Guide - Page 183
    de lutter contre l'impact néfaste potentiel de ce type de produits sur l'environnement et la santé publique. Pour plus d'informations sur le mode d'élimination de Linksys ATA Administration Guide 183
  • Linksys RTP300 | User Guide - Page 184
    EC on Waste votre ancien équipement, veuillez prendre contact avec les pouvoirs publics locaux, le service de traitement des déchets, ou l'endroit où vous avez acheté le produit. Italiano (Italian - Környezetvédelmi információ az európai uniós vásárlók számára Linksys ATA Administration Guide 184
  • Linksys RTP300 | User Guide - Page 185
    2002/96/CE exige que o equipamento que exibe este símbolo no produto e/ou na sua embalagem não seja eliminado junto com os resíduos municipais não separados. O Linksys ATA Administration Guide 185
  • Linksys RTP300 | User Guide - Page 186
    kielteiset vaikutukset ympäristöön ja ihmisten terveyteen. Lisätietoja vanhan laitteiston oikeasta hävitystavasta saa paikallisilta viranomaisilta, jätteenhävityspalvelusta tai siitä myymälästä, josta ostit tuotteen. Linksys ATA Administration Guide 186
  • Linksys RTP300 | User Guide - Page 187
    konsekvenser för miljön och personhälsa. För mer detaljerad information om kassering av din gamla utrustning kontaktar du dina lokala myndigheter, avfallshanteringen eller butiken där du köpte produkten. Linksys ATA Administration Guide 187
  • Linksys RTP300 | User Guide - Page 188
    , and WAN ports contain TNV circuits. Some LAN and WAN ports both use RJ-45 connectors. Use caution when connecting cables. WARNING: Equipment Installation Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Linksys ATA Administration Guide 188
  • Linksys RTP300 | User Guide - Page 189
    that the protective device is rated not greater than: 120 VAC, 15A U.S. (240 VAC, 10A international) WARNING: Warning Main Disconnecting Device The plug-socket combination must be accessible at all times, because it serves as the main disconnecting device. Linksys ATA Administration Guide 189
  • Linksys RTP300 | User Guide - Page 190
    may also be prompted to review and accept that Linksys Software License Agreement upon installation of the software. Any software from the open source community is licensed under the specific license terms applicable to that software made available by Linksys at www.linksys.com/gpl or as provided
  • Linksys RTP300 | User Guide - Page 191
    Source Software. The GPL or other open source code incorporated into the Software and the open source license for such source code are available for free download at http:// www.linksys.com/gpl. If You would like a copy of the GPL or other open source code in this Linksys ATA Administration Guide
  • Linksys RTP300 | User Guide - Page 192
    2 will apply to that open source software. The license terms below in this Schedule 2 are from the public web site at http://www.gnu.org/copyleft/gpl.html GNU GENERAL PUBLIC LICENSE Version 2, June 1991 Copyright (C) 1989, 1991 Free Software Foundation, Inc. Linksys ATA Administration Guide 192
  • Linksys RTP300 | User Guide - Page 193
    to distribute copies of free software (and charge for this service if you wish), that you problems introduced by others will not reflect on the original authors' reputations. Finally, any free program is threatened constantly by software addressed as "you". Linksys ATA Administration Guide 193
  • Linksys RTP300 | User Guide - Page 194
    Software Licenses: Activities other than copying, distribution and modification are not covered by this License; they are outside its scope. Program) on a volume of a storage or distribution medium does not bring the other work under the scope of this License. Linksys ATA Administration Guide 194
  • Linksys RTP300 | User Guide - Page 195
    which must be distributed under the terms of Sections 1 and 2 above on a medium customarily used for software interchange; or, b) Accompany it with a written offer, valid for at least three years, to for enforcing compliance by third parties to this License. Linksys ATA Administration Guide 195
  • Linksys RTP300 | User Guide - Page 196
    to address new problems or software and of promoting the sharing and reuse of software generally. NO WARRANTY 11. BECAUSE THE PROGRAM IS LICENSED FREE OF CHARGE, THERE IS NO WARRANTY FOR THE PROGRAM, TO THE EXTENT PERMITTED BY APPLICABLE LAW. EXCEPT WHEN OTHERWISE Linksys ATA Administration Guide
  • Linksys RTP300 | User Guide - Page 197
    THE PROGRAM PROVE DEFECTIVE, YOU ASSUME THE COST OF ALL NECESSARY SERVICING, REPAIR OR CORRECTION. 12. IN NO EVENT UNLESS REQUIRED BY OF SCHEDULE 2 Schedule 3 If this Linksys product contains open source software licensed under the OpenSSL license then the license Linksys ATA Administration Guide 197
  • Linksys RTP300 | User Guide - Page 198
    written permission, please contact [email protected]. 5. Products derived from this software may not be called "OpenSSL" nor may "OpenSSL" appear in their names without prior written permission such any Copyright notices in the code are not to be removed. Linksys ATA Administration Guide 198
  • Linksys RTP300 | User Guide - Page 199
    specific code (or a derivative thereof ) from the apps directory (application code) you must include an acknowledgement: "This product includes software written by Tim Hudson ([email protected])" THIS SOFTWARE OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA Linksys ATA Administration Guide 199
  • Linksys RTP300 | User Guide - Page 200
    http://www.linksys.com FTP Site ftp://ftp.linksys.com Support http://www.linksys.com/support Sales Information 800-546-5797 (800-LINKSYS) Global Contacts Website http://www.linksys.com/international Product Registration http://www.linksys.com/registration Linksys ATA Administration Guide 200
  • Linksys RTP300 | User Guide - Page 201
    080815A-IH
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201

ADMINISTRATION
GUIDE
Linksys
ATA Administration Guide
, Version 2.0