Distinctive Ring Settings Ring Settings Never, Automatic, Manual, Source, Mirror.

Page 159 highlights

User page Field Description Accept Media Loopback Request Controls how to handle incoming requests for loopback operation. Choices are: Never, Automatic, and Manual, where: • never-never accepts loopback calls; reply 486 to the caller • automatic-automatically accepts the call without ringing • manual -rings the phone first, and the call must be picked up manually before loopback starts. The default is Automatic. Media Loopback Mode The loopback mode to assume locally when making call to request media loopback. Choices are: Source and Mirror. Default is Source. Note that if the Linksys ATA device answers the call, the mode is determined by the caller. Media Loopback Type The loopback type to use when making call to request media loopback operation. Choices are Media and Packet. Default is Media. Note that if the Linksys ATA device answers the call, then the loopback type is determined by the caller (the Linksys ATA device always picks the first loopback type in the offer if it contains multiple types.) Voice tab > User page > Distinctive Ring Settings section Caller number patterns are matched from Ring 1 to Ring 8. The first match (not the closest match) will be used for alerting the subscriber. Field Ring1 - 9 Caller Description Caller number pattern to play Distinctive Ring/CWT 1, 2, 3, 4, 5, 6, 7, 8, or 9. The default is blank. Voice tab > User page > Ring Settings section Field Default Ring Default CWT Hold Reminder Ring Call Back Ring Cfwd Ring Splash Len Cblk Ring Splash Len Description Default ringing pattern, 1 - 8, for all callers. The default is 1. Default CWT pattern, 1 - 8, for all callers. The default is 2. Ring pattern for reminder of a holding call when the phone is on-hook. The default is None. Ring pattern for call back notification. The default is None. Duration of ring splash when a call is forwarded (0 - 10.0s). The default is 0. Duration of ring splash when a call is blocked (0 - 10.0s). The default is 0. Linksys ATA Administration Guide 159

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201

Linksys ATA Administration Guide
159
User page
Voice tab > User page >
Distinctive Ring Settings section
Caller number patterns are matched from Ring 1 to Ring 8. The first match (not the closest
match) will be used for alerting the subscriber.
Voice tab > User page >
Ring Settings section
Accept Media Loopback
Request
Controls how to handle incoming requests for loopback operation. Choices
are:
Never
,
Automatic
, and
Manual
, where:
never
—never accepts loopback calls; reply 486 to the caller
automatic
—automatically accepts the call without ringing
manual
—rings the phone first, and the call must be picked up manually
before loopback starts.
The default is
Automatic
.
Media Loopback Mode
The loopback mode to assume locally when making call to request media
loopback. Choices are:
Source
and
Mirror.
Default is
Source
.
Note that if the Linksys ATA device answers the call, the mode is determined
by the caller.
Media Loopback Type
The loopback type to use when making call to request media loopback
operation. Choices are Media and Packet. Default is
Media
.
Note that if the Linksys ATA device answers the call, then the loopback type is
determined by the caller (the Linksys ATA device always picks the first
loopback type in the offer if it contains multiple types.)
Field
Description
Ring1 - 9 Caller
Caller number pattern to play Distinctive Ring/CWT 1, 2, 3, 4, 5, 6, 7, 8, or 9.
The default is
blank
.
Field
Description
Default Ring
Default ringing pattern, 1 – 8,
for all callers.
The default is
1
.
Default CWT
Default CWT pattern, 1 – 8, for all callers.
The default is
2
.
Hold Reminder Ring
Ring pattern for reminder of a holding call when the phone is on-hook.
The default is
None
.
Call Back Ring
Ring pattern for call back notification.
The default is
None
.
Cfwd Ring Splash Len
Duration of ring splash when a call is forwarded
(0 – 10.0s).
The default is
0
.
Cblk Ring Splash Len
Duration of ring splash when a call is blocked (0 – 10.0s).
The default is
0
.
Field