Linksys RTP300 User Guide - Page 156

User

Page 156 highlights

User page Field Ring Frequency Max Ring Validation Time Ring Indication Delay Ring Timeout Ring Threshold Ringer Impedance Line-In-Use Voltage Description Maximum ring frequency to detect. The range is 5-100. The default is 100. Choose from {100, 150, 200, 256, 384, 512, 640, 1024} (ms). The default is 256ms. Choose from {0, 512, 768, 1024, 1280, 1536, 1792} (ms). The default is 512ms. Choose from {0, 128, 256, 384, 512, 640, 768, 896, 1024, 1152, 1280, 1408, 1536, 1664, 1792, 1920} (ms). The default is 640 ms. Choose from {13.5-16.5, 19.35-2.65, 40.5-49.5} (Vrms). The default is 13.5-16.5 Vrms. Choose from {High, Synthesized(Poland, S.Africa, Slovenia)}. The default is high. Determines the voltage threshold at which the SPA-3000 assumes the PSTN is in use by another handset sharing the same line (and will declare PSTN gateway service not available to incoming VoIP callers). The default value is 40v. Voice tab > User page Depending on the model of ATA device, there may be one or more User pages. You can use this page to configure the user settings. This page includes the following sections: • "Call Forward Settings section" section on page 157 • "Selective Call Forward Settings section" section on page 157 • "Speed Dial Settings section" section on page 158 • "Supplementary Service Settings section" section on page 158 • "Distinctive Ring Settings section" section on page 159 • "Ring Settings section" section on page 159 NOTE: For the SPA8000, the settings on this page occur on each Line tab ([1] to [8]). When a call is made from Line 1 or Line 2, the ATA device shall use the user and line settings for that line; there is no user login support. Per user parameter tags must be appended with [1] or [2] (corresponding to line 1 or 2) in the configuration profile. It is omitted below for readability. Linksys ATA Administration Guide 156

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201

Linksys ATA Administration Guide
156
User page
Voice tab >
User page
Depending on the model of ATA device, there may be one or more User pages. You can use this
page to configure the user settings. This page includes the following sections:
”Call Forward Settings section” section on page 157
”Selective Call Forward Settings section” section on page 157
”Speed Dial Settings section” section on page 158
”Supplementary Service Settings section” section on page 158
”Distinctive Ring Settings section” section on page 159
”Ring Settings section” section on page 159
NOTE:
For the SPA8000, the settings on this page occur on each Line tab ([1] to [8]).
When a call is made from Line 1 or Line 2, the ATA device shall use the user and line settings for
that line; there is no user login support. Per user parameter tags must be appended with [1] or
[2] (corresponding to line 1 or 2) in the configuration profile. It is omitted below for readability.
Ring Frequency Max
Maximum ring frequency to detect. The range is 5-100.
The default is
100
.
Ring Validation Time
Choose from {100, 150, 200, 256, 384, 512, 640, 1024} (ms).
The default is
256ms
.
Ring Indication Delay
Choose from {0, 512, 768, 1024, 1280, 1536, 1792} (ms).
The default is
512ms
.
Ring Timeout
Choose from {0, 128, 256, 384, 512, 640, 768, 896, 1024, 1152, 1280, 1408,
1536, 1664, 1792, 1920} (ms).
The default is
640 ms
.
Ring Threshold
Choose from {13.5–16.5, 19.35–2.65, 40.5–49.5} (Vrms).
The default is
13.5-16.5 Vrms
.
Ringer Impedance
Choose from {High, Synthesized(Poland, S.Africa, Slovenia)}.
The default is
high
.
Line-In-Use Voltage
Determines the voltage threshold at which the SPA-3000 assumes the PSTN
is in use by another handset sharing the same line (and will declare PSTN
gateway service not available to incoming VoIP callers).
The default value is
40v
.
Field
Description