Linksys RTP300 User Guide - Page 155
International Control (Settings) nF, 220+820||120nF
UPC - 745883565658
View all Linksys RTP300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 155 highlights
PSTN Line page (AG310 and SPA3102) Voice tab > PSTN Line page > International Control (Settings) section Field Description FXO Port Impedance Desired impedance of the FXO Port. Choose from {600, 900, 370+620, 270+750||150nF, 220+820||120nF, 370 + 620 || 310nf, 320 + 1050 || 230nf, 370 + 820 || 110 nf, 275 + 780 || 115nf, 120 + 820 || 110nf, 350 + 1000 || 210nf, 0 + 900 || 130nf } The default is 600. The Disconnect Tone Script and Impedance values for various countries follos: US-480@-30,620@-30;4(.25/.25/1+2) -Impedance: 600 UK-400@-30,400@-30; 2(3/0/1+2) -Impedance: 370+620 France-440@-30,440@-30; 2(0.5/0.5/1+2) -Impedance: 270+750||150nF Germany-425@-10; 10(0.48/0.48/1) -Impedance:220+820||120nF Netherlands-425@-30,425@-30; 2(0.5/0.5/1+2) -Impedance: 600 Sweden-425@-10; 10(0.25/0.25/1) -Impedance:600 Norway-425@-10; 10(0.5/0.5/1) -Impedance: 600 Italy-425@-30,425@-30; 2(0.2/0.2/1+2)- Impedance: 220+820||120nF Spain-425@-10; 10(0.2/0.2/1,0.2/0.2/1,0.2/0.6/1) -Impedance: 220+820||120nF Portugal-425@-10; 10(0.5/0.5/1)- Impedance:220+820||120nF Poland-425@-10; 10(0.5/0.5/1)- Impedance: n/a Denmark-425@-10; 10(0.25/0.25/1)- Impedance: 600 Ring Frequency Min Specify the lower limit of the ring frequency used to detect the ring signal. The default is 10. SPA To PSTN Gain dB of digital gain (or attenuation if negative) to be applied to the signal sent from the SPA to the PSTN side. The range is -15 to 12. The default is 0. Ring Frequency Max Specify the higher limit of the ring frequency used to detect the ring signal. The default is 100. PSTN To SPA Gain dB of digital gain (or attenuation if negative) to be applied to the signal sent from the PSTN side to the SPA. The range is -15 to 12. The default is 0. Ring Validation Time Specify the minimum signal duration required by the Gateway for recognition as a ring signal. The default is 256 ms. Tip/Ring Voltage Adjust Choices are {3.1, 3.2, 3.35, 3.5}. The default is 3.5. Operational Loop Current Min Choices for mA are: {10, 12, 14, 16). The default is 10. On-Hook Speed Choose from {Less than 0.5ms, 3ms (ETSI), 26ms (Australia)}. The default is Less than 0.5ms. Current Limiting Enable Enable or disable current limiting. The default is no. Ring Frequency Min Minimum ring frequency to detect. The range is 5-100. The default is 10. Linksys ATA Administration Guide 155