Chapter 2 Location and Function of Parts b LCD 1 System information HOME VIDEO IN SDI EDIT E.PRESET CLR CNT 59.94 SDI 10801080 2F ASM CONFI LTC D F VITC LTC EXT-LTC R-RUN PARARUN 12:34:47:12 HD PROLL BANK3 R E M : 2 0 m i n COND 3+4 2 EMPH dB DATA 0 -10 1 4 EMPH dB DATA 0 dB -10 10 -20 -20 -20 -30 -40 -60 L1R L2R SDI1 ANA2 L3R SDI3 -30 -40 -60 L4R AES4 -10 -20 -40 L CUE R 3+4 HOME PB/EE PB CONFI ENABLE COUNTER CTL MENU TCG SET 3 Audio level meter block 1 4 Audio level meter block 2 5 Time data information 6 Information relating to timecode 2 Function menu information The LCD has the following display modes. • Video display mode: The LCD displays the video signals currently being recorded or played back. • Function display mode: The LCD displays timecode, important information about the operating state, audio level meter values, and function menu information. • Function & video display mode: The LCD displays timecode, important information about the operating state, audio level meter values, function menu information, and the video signals currently being recorded or played back. To change the display mode Pressing the DISPLAY button toggles the display mode between video display mode and function display mode. Note The function menu cannot be operated in video display mode. For details on the function menu, see page 64. Video display mode In video display mode, the video signals currently being recorded or played back appear on the full screen of the LCD. Function display mode The following describes the items shown in the function display mode. 1 System information System frequency Output line information Edit state indication 59.94 SDI 0 1100880 LTC D F VITC LTC EXT LTC 2F ASM CONFI R RUN PARARUN CONFI/PREREAD indication Capstan lock indication Video input signal • System frequency During operation the system frequency is indicated as 59.94, 50, 29.97PsF, 25PsF, 24PsF or 23.98PsF. • Output line information Output line information is indicated as shown below. "VIN 1080": The unit is in E-E mode. "1080": The unit is in PB mode. "60Hz >> 1080": An HDCAM tape containing material recorded at different frequencies is currently being played back. 14 2-1 Control Panels

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121

14
2-1
Control Panels
Chapter 2
Location and Function of Parts
b
LCD
The LCD has the following display modes.
Video display mode:
The LCD displays the video
signals currently being recorded or played back.
Function display mode:
The LCD displays timecode,
important information about the operating state, audio
level meter values, and function menu information.
Function & video display mode:
The LCD displays
timecode, important information about the operating
state, audio level meter values, function menu
information, and the video signals currently being
recorded or played back.
To change the display mode
Pressing the DISPLAY button toggles the display mode
between video display mode and function display mode.
The function menu cannot be operated in video display
mode.
For details on the function menu, see page 64.
Video display mode
In video display mode, the video signals currently being
recorded or played back appear on the full screen of the
LCD.
Function display mode
The following describes the items shown in the function
display mode.
1
System information
System frequency
During operation the system frequency is indicated as
59.94, 50, 29.97PsF, 25PsF, 24PsF or 23.98PsF.
Output line information
Output line information is indicated as shown below.
“VIN 1080”:
The unit is in E-E mode.
“1080”:
The unit is in PB mode.
“60Hz >> 1080”:
An HDCAM tape containing material
recorded at different frequencies is currently being
played back.
12 34
:
47 12
:
:
59.94
SDI
2F
ASM
LTC
1080
1080
DF
LTC
EXT-LTC
R-RUN
PROLL
HOME
VIDEO IN
SDI
EDIT
E.PRESET
CLR CNT
HOME
PB/EE
PB
CONFI
ENABLE
COUNTER
CTL
MENU
TCG SET
L
R
1
SDI1
3+4
BANK3
REM:20min
HD
COND
VITC
L
R
2
ANA2
2
-60
-40
-30
-20
-10
0
dB
L
R
3
SDI3
1
L
R
4
AES4
4
-60
-40
-30
-20
-10
0
dB
L
R
CUE
3+4
-40
-20
-10
-20
10
dB
EMPH
DATA
EMPH
DATA
CONFI
PARARUN
2
Function menu information
1
System information
3
Audio level meter block 1
4
Audio level meter block 2
6
Information relating to timecode
5
Time data information
Note
LTC
DF
LTC
EXT LTC
R RUN
PARARUN
VITC
59.94
SDI
2F
ASM
CONFI
108
0
1080
System frequency
Output line information
Edit state indication
CONFI/PREREAD indication
Capstan lock indication
Video input signal