Sony STR-DA4300ES Operating Instructions (Large File - 20.21 MB) - Page 117

To operate on the receiver, To confirm/save auto calibration, when GUI function is turned off

Page 117 highlights

Performing auto calibration For details on the auto calibration, see "9: Calibrating the appropriate speaker settings automatically (Auto Calibration)" (page 44). Refer to "Before you perform the auto calibration" (page 44) before performing the auto calibration. To operate on the receiver 1 Press SHIFT, then press MENU to switch from "GUI MODE" to "DISPLAY MODE". 2 Press AMP. Receiver operation is enabled. 3 Press MENU. "Auto Calibration" is displayed. 4 Press . 5 Press V/v repeatedly to select "AUTO CAL START?," then press to start the measurement. Measurement starts in five seconds. A count down is displayed. Note While the time is counting down, stand away from the measurement area to avoid measurement error. 6 Measurement starts. The measurement process will take approximately 30 seconds. Wait until the measurement process completes. To cancel auto calibration, change the volume, activate the MUTING function, switch functions, change the setting of the SPEAKERS switch of the receiver, or connect headphones. Note You cannot measure the speaker height of the surround speakers and the surround back speakers. Set this value from "SP POSI." settings in the Speaker settings menu. Tips • Operations other than turning the receiver on or off are deactivated during auto calibration. • In the following situations, the measurements may not be performed correctly or auto calibration cannot be performed. - when special speakers, such as dipole speakers are used. - when the multi zone function is used in zone 2. To confirm/save auto calibration when GUI function is turned off 1 Confirm the measurement result. When the measurement ends, a beep sounds and the measurement result appears on the display. Measurement Display Explanation result When the measurement process completes properly COMPLETE Proceed to step 2. When the measurement process fails ERROR CODE 3x See "Message list after auto calibration measurement" (page 49). 2 Press V/v repeatedly to select the item, then press . The measurement results are saved. Item Explanation RETRY Re-performs the auto calibration. SAVE EXIT Saves the measurement results and exits the setting process. WRN CHECK Displays a warning concerning the measurement results. See "When you select "WRN CHECK"" (page 49). PHASE INFO Displays the phase of each speaker (in phase/out of phase). See "When you select "PHASE INFO"". DIST.INFO Displays the measurement result for speaker distance. Other Operations continued 117GB

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302

117
GB
Other Operations
For details on the auto calibration, see “9:
Calibrating the appropriate speaker settings
automatically (Auto Calibration)” (page 44).
Refer to “Before you perform the auto
calibration” (page 44) before performing the
auto calibration.
To operate on the receiver
1
Press SHIFT, then press MENU to
switch from “GUI MODE” to “DISPLAY
MODE”.
2
Press AMP.
Receiver operation is enabled.
3
Press MENU.
“Auto Calibration” is displayed.
4
Press
.
5
Press
V
/
v
repeatedly to select “AUTO
CAL START?,” then press
to start
the measurement.
Measurement starts in five seconds. A
count down is displayed.
Note
While the time is counting down, stand away
from the measurement area to avoid
measurement error.
6
Measurement starts.
The measurement process will take
approximately 30 seconds. Wait until the
measurement process completes.
To cancel auto calibration, change the volume,
activate the MUTING function, switch
functions, change the setting of the
SPEAKERS switch of the receiver, or connect
headphones.
Note
You cannot measure the speaker height of the
surround speakers and the surround back speakers.
Set this value from “SP POSI.” settings in the
Speaker settings menu.
Tips
• Operations other than turning the receiver on or off
are deactivated during auto calibration.
• In the following situations, the measurements may
not be performed correctly or auto calibration
cannot be performed.
when special speakers, such as dipole speakers
are used.
when the multi zone function is used in zone 2.
To confirm/save auto calibration
when GUI function is turned off
1
Confirm the measurement result.
When the measurement ends, a beep
sounds and the measurement result appears
on the display.
2
Press
V
/
v
repeatedly to select the item,
then press
The measurement results are saved.
Performing auto calibration
Measurement
result
Display
Explanation
When the
measurement
process
completes
properly
COMPLETE
Proceed to step
2.
When the
measurement
process fails
ERROR
CODE
3
x
See “Message
list after auto
calibration
measurement”
(page 49).
Item
Explanation
RETRY
Re-performs the auto
calibration.
SAVE EXIT
Saves the measurement
results and exits the setting
process.
WRN CHECK
Displays a warning
concerning the measurement
results. See “When you select
“WRN CHECK”” (page 49).
PHASE INFO
Displays the phase of each
speaker (in phase/out of
phase). See “When you select
“PHASE INFO””.
DIST.INFO
Displays the measurement
result for speaker distance.
continued