Adaptec 3200S User Guide - Page 115

RAID Operation, -C Load/save configuration, -r Specify task rate, -w Write caching

Page 115 highlights

RAIDUTIL Command Line Utility RAID Operation -C Load/save configuration This switch has two options: load Loads the specified configuration file save Saves the current configuration to the file name specified A file name must follow the load or save parameter. This is a .dsm file, which can also be loaded or saved using Storage Manager. -r Specify task rate This switch sets a task priority for the device or logical drive. The parameter can be 0 - 9; with 0 being the slowest and 9 being the fastest. You can also specify the rate as follows: -r slow = 1 -r medslow = 3 -r med = 5 -r medfast = 7 -r fast = 9 The device address is required. Specify logical drives by their device addresses. You can set the rate for all logical drives on a controller by using the device address of the controller. -w Write caching Options are On and Off. The default (On) uses Write-Back caching. Off sets the operation to Write-Through caching. Specify drives using the device address. 4-7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135

4-7
RAIDUTIL Command Line Utility
RAID Operation
-C
Load/save configuration
This switch has two options:
A file name must follow the load or save parameter. This is a .
dsm
file, which can also be loaded or saved using Storage Manager.
-r
Specify task rate
This switch sets a task priority for the device or logical drive. The
parameter can be 0 – 9; with 0 being the slowest and 9 being the
fastest. You can also specify the rate as follows:
The device address is required. Specify logical drives by their device
addresses. You can set the rate for all logical drives on a controller by
using the device address of the controller.
-w
Write caching
Options are On and Off. The default (
On
) uses Write-Back caching.
Off sets the operation to Write-Through caching. Specify drives
using the device address.
load
Loads the specified configuration file
save
Saves the current configuration to the file name
specified
-r slow
= 1
-r medslow
= 3
-r med
= 5
-r medfast
= 7
-r fast
= 9