Adaptec 3200S User Guide - Page 29

SCSI RAID controllers are con d by default at ID 7. This value

Page 29 highlights

Storage Manager on ROM Select Default to reset the parameters on this tab to their default values (SCSI only). Controller Parameter ID Type Width Transfer Rate Termination TERMPWR Default 7 As reported As reported Maximum allowed for the controller Auto On Available Settings SCSI: 0 - 6 ATA: not shown N/A N/A Ultra3, Ultra2, Ultra, 10, 8, 5 Asynchronous On, Off, High Only Auto, Off Note: As reported means that the field displays the value returned by the controller firmware. Bus Each peripheral bus on a controller is assigned a number. Numbering starts with 0 for the first bus, 1 for the second bus, and so on. ID (SCSI only) SCSI RAID controllers are configured by default at ID 7. This value should not be changed unless required for special configurations. Type This is the type of bus (Ultra, Ultra2, Ultra3, ATA/100, etc.). Width (SCSI only) The width of the parallel bus (8-bit or 16-bit). 2-18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135

2-18
Storage Manager on ROM
Select
Default
to reset the parameters on this tab to their default
values (SCSI only).
Note:
As reported
means that the field displays the value
returned by the controller firmware.
Bus
Each peripheral bus on a controller is assigned a number.
Numbering starts with 0 for the first bus, 1 for the second bus, and
so on.
ID (SCSI only)
SCSI RAID controllers are configured by default at ID 7. This value
should not be changed unless required for special configurations.
Type
This is the type of bus (Ultra, Ultra2, Ultra3, ATA/100, etc.).
Width (SCSI only)
The width of the parallel bus (8-bit or 16-bit).
Controller Parameter
Default
Available Settings
ID
7
SCSI: 0 – 6
ATA: not shown
Type
As reported
N/A
Width
As reported
N/A
Transfer Rate
Maximum allowed
for the controller
Ultra3, Ultra2, Ultra,
10, 8, 5 Asynchronous
Termination
Auto
On, Off, High Only
TERMPWR
On
Auto, Off