Adaptec 3200S User Guide - Page 30
Configuring Termination, Adaptec RAID Installation Guide, bit Narrow cable. Refer to
UPC - 760884136430
View all Adaptec 3200S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
Storage Manager on ROM Transfer Rate (SCSI only) The controller automatically negotiates with each device at powerup or reset to set the maximum transfer rate. This parameter limits the transfer rate to the value selected. This setting should not be changed except when you are troubleshooting bus errors. Note: On buses, if setting this parameter to 5 MHz eliminates bus data errors, this is usually an indication that the bus is too long or that the bus is not terminated correctly. Termination (SCSI only) This option controls the termination for the controller and bus. The default value (Auto) should not be changed unless both internal and external cables are attached to the controller or you are using an 8-bit (Narrow) cable. Refer to the Configuring Termination section in the Adaptec RAID Installation Guide for information on setting this parameter. TERMPWR (SCSI only) By default RAID controllers supply termination power for other devices through the TERMPWR line on the cable. 2-19