Asus Adaptec 2020 ZCR User Manual - Page 75

Controller Configuration Options, Adaptec RAID Configuration Utility ARC

Page 75 highlights

Adaptec RAID Configuration Utility (ARC) Controller Configuration Options The Controller Configuration options are described in the table below. Option Drives Write Cache Runtime BIOS Automatic Failover Array Background Consistency Check BBS Support Default Drive's Default Enabled Enabled Disabled Enabled Models Affected All All All All See note 1 Description When Enabled, write cache is enabled, providing maximum drive performance. When Disabled, no write cache is used on the drive. By default, the drive's setting is used. Caution-When Enabled, there is a slight possibility (less than with controller cache) of data loss or corruption during a power failure. When Enabled, the controller BIOS allows the controller to act as a bootable device. Disabling the BIOS allows another suitable controller to act as the boot device. When Enabled, the controller automatically rebuilds an array when the failed drive is replaced. When disabled, the array must be rebuilt manually. When Enabled, the controller constantly performs a verification on a redundant array to data integrity. In the case of RAID 1 or 10, consistency checks assure that the data between like blocks match. In the case of a RAID 5 or a RAID 0, consistency checks assure that data in the stripe and the calculated parity for the stripe match. Consistency checking processes reduce performance. For a RAID 5 or a RAID 50, the performance reduction is significant. When Enabled in systems that support BBS, controller is presented as a bootable device in the host system's BIOS for boot device selection. A-10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169

A-10
Adaptec RAID Configuration Utility (ARC)
Controller Configuration Options
The Controller Configuration options are described in the table
below.
Option
Default
Models
Affected
Description
Drives Write
Cache
Drive's
Default
All
When
Enabled
, write cache is
enabled, providing maximum drive
performance. When
Disabled
, no
write cache is used on the drive. By
default, the drive’s setting is used.
Caution
—When
Enabled
, there is a
slight possibility (less than with
controller cache) of data loss or
corruption during a power failure.
Runtime BIOS
Enabled
All
When
Enabled
, the controller BIOS
allows the controller to act as a
bootable device. Disabling the BIOS
allows another suitable controller to
act as the boot device.
Automatic
Failover
Enabled
All
When
Enabled
, the controller
automatically rebuilds an array
when the failed drive is replaced.
When disabled, the array must be
rebuilt manually.
Array
Background
Consistency
Check
Disabled
All
When
Enabled
, the controller
constantly performs a verification
on a redundant array to data
integrity. In the case of RAID 1 or 10,
consistency checks assure that the
data between like blocks match. In
the case of a RAID 5 or a RAID 0,
consistency checks assure that data
in the stripe and the calculated
parity for the stripe match.
Consistency checking processes
reduce performance. For a RAID 5
or a RAID 50, the performance
reduction is significant.
BBS Support
Enabled
See
note
1
When
Enabled
in systems that
support BBS, controller is presented
as a bootable device in the host
system's BIOS for boot device
selection.