Asus Adaptec 2020 ZCR User Manual - Page 91

Type Keyword, Wait Keyword, WriteCache Keyword, wait=no, Wait=Yes, WriteCache, Volume, RAID5

Page 91 highlights

ACU for DOS Type Keyword Type is a required keyword, indicating the array type. There is no default value. The Type keyword values are: ■ Volume ■ RAID5 ■ RAID0 ■ RAID10 ■ RAID1 ■ RAID50 Note: For information about which array types your controller supports, see Controller Features on page 1-5. Wait Keyword Wait is an optional keyword that you can use to tell the ACU to allow the ACU to continue while the build/verify or clear completes in the background; specify wait=no. Otherwise, the ACU waits by default. Note: If the host is powered off before the build/verify or clear process completes and is then restarted, the process resumes without any user intervention. Examples Wait=Yes Wait=No WriteCache Keyword The WriteCache keyword indicates whether write caching is used for this array if write caching is supported for the system. Possible values are as follows: ■ Yes (the default)-Enable the write cache. ■ No-Disable the write cache. Note: Setting an array's WriteCache keyword to Yes might result in data loss or corruption during a power failure. Example WriteCache=Yes B-11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169

B-11
ACU for DOS
Type Keyword
Type
is a required keyword, indicating the array type. There is no
default value. The
Type
keyword values are:
Note:
For information about which array types your controller
supports, see
Controller Features
on page 1-5
.
Wait Keyword
Wait
is an optional keyword that you can use to tell the ACU to
allow the ACU to continue while the build/verify or clear
completes in the background; specify
wait=no
. Otherwise, the
ACU waits by default.
Note:
If the host is powered off before the build/verify or clear
process completes and is then restarted, the process resumes
without any user intervention.
Examples
Wait=Yes
Wait=No
WriteCache Keyword
The
WriteCache
keyword indicates whether write caching is used
for this array if write caching is supported for the system. Possible
values are as follows:
Yes
(the
default
)—Enable the write cache.
No
—Disable the write cache.
Note:
Setting an array’s
WriteCache
keyword to
Yes
might
result in data loss or corruption during a power failure.
Example
WriteCache=Yes
Volume
RAID5
RAID0
RAID10
RAID1
RAID50