Specifying Lamp Control
View all Canon REALiS WUX6000 D Pro AV manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 94 highlights
Adjusting Image Quality (Image Adjustment) • The adjustments you have made are stored as adjusted values for the input signals and image mode of the current projection. • For details of gamma correction, refer to page 87. • Adjustment is not applied to the projected menu itself. Perform adjustment using input signals or a built-in test pattern. Specifying Lamp Control > [Image adjustment] > [Advanced adjustment] > [Lamp control] HDMI Digital PC Component Analog PC LAN USB Dims the lamp automatically when the input signal is completely black. Off No lamp control. On Lamp control. Dims the lamp in response to fully black input signals. Normal brightness is restored once the input signal changes from fully black. Press the OK button to accept your setting and then press the MENU button. • [Off] is the factory default. • The projector automatically enters standby mode if the lamp is dimmed (that is, if the input signal is fully black) for more than one hour. A countdown window is displayed 10 minutes before entering standby. • The lamp is not dimmed when projection is blanked, when no signals are supplied, or when black is projected during gamma restore. • Lamp control is not available for the following settings: - In split-screen mode - During test pattern projection - When [Lamp mode] is set to [Power saver] - When [Vertical projection] is set to [Upward] or [Downward] - When [Fan mode] is set to [High altitude] • No lamp control is performed in the first 20 minutes after the projector is turned on. 94