Cisco 4948 Installation Guide - Page 23

Physical and Environmental Specifications - s weight

Page 23 highlights

Chapter 1 Product Overview Physical and Environmental Specifications Physical and Environmental Specifications Table 1-2 lists the Catalyst 4948E and Catalyst 4948E-F switch chassis environmental and physical specifications. Table 1-2 Catalyst 4948E and Catalyst 4948E-F Switch Specifications Item Environmental Temperature, operating Temperature, nonoperating and storage Thermal transition Humidity (RH), ambient (noncondensing) operating Altitude, operating Heat Dissipation Shock and vibration Acoustic noise Physical Characteristics Dimensions (H x W x D) Weight Airflow Specification Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 131°F (0° to 55°C) Chassis unpackaged: -4° to 149°F (-20° to 65°C) Chassis in protective shipping package: -40° to 158°F (-40° to 70°C) 0.5°C per minute (hot to cold) 0.33°C per minute (cold to hot) Operating: 5% to 90% Nonoperating and storage: 5% to 95% Certified for operation: 0 to 6500 ft (0 to 2000 m) Designed and tested for operation: -200 to 10,000 ft (-60 to 3000 m) 1364 BTU/hour (worst case) Refer to Appendix D, "Regulatory Compliance and Safety Information" for shock and vibration compliance information for the switch. Refer to Appendix D, "Regulatory Compliance and Safety Information" for acoustic noise compliance information for the switch. • 1.75 x 17.5 x 19.4 in. (4.4 x 44.4 x 49.3 cm). • Chassis requires 1 RU. • The Catalyst 4948E and the Catalyst 4948E-F switch chassis are designed to install in standard 19-inch equipment racks that meet ANSI/EIA 310-D, IEC 60297, and ETS 300-119 standards. • 14 lb (6.35 kg). Base system; no power supplies and no fan tray. • 19 lb (8.62 kg). Fully loaded system; two power supplies and a fan tray. • 28 CFM (low speed) • 44 CFM (high speed) OL-21561-02 Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide 1-7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162

1-7
Catalyst 4948E and Catalyst 4948E-F
Switch Installation Guide
OL-21561-02
Chapter 1
Product Overview
Physical and Environmental Specifications
Physical and Environmental Specifications
Table 1-2
lists the Catalyst 4948E and Catalyst 4948E-F switch chassis environmental and physical
specifications.
Table 1-2
Catalyst 4948E and Catalyst 4948E-F Switch Specifications
Item
Specification
Environmental
Temperature, operating
Certified for operation: 32° to 104°F (0° to 40°C)
Designed and tested for operation: 32° to 131°F (0° to 55°C)
Temperature, nonoperating
and storage
Chassis unpackaged: –4° to 149°F (–20° to 65°C)
Chassis in protective shipping package: –40° to 158°F (–40° to 70°C)
Thermal transition
0.5°C per minute (hot to cold)
0.33°C per minute (cold to hot)
Humidity (RH), ambient
(noncondensing) operating
Operating: 5% to 90%
Nonoperating and storage: 5% to 95%
Altitude, operating
Certified for operation: 0 to 6500 ft (0 to 2000 m)
Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m)
Heat Dissipation
1364 BTU/hour (worst case)
Shock and vibration
Refer to
Appendix D, “Regulatory Compliance and Safety Information”
for
shock and vibration compliance information for the switch.
Acoustic noise
Refer to
Appendix D, “Regulatory Compliance and Safety Information”
for
acoustic noise compliance information for the switch.
Physical Characteristics
Dimensions (H x W x D)
1.75 x 17.5 x 19.4 in. (4.4 x 44.4 x 49.3 cm).
Chassis requires 1 RU.
The Catalyst 4948E and the Catalyst 4948E-F switch chassis are
designed to install in standard 19-inch equipment racks that meet
ANSI/EIA 310-D, IEC 60297, and ETS 300-119 standards.
Weight
14 lb (6.35 kg). Base system; no power supplies and no fan tray.
19 lb (8.62 kg). Fully loaded system; two power supplies and a fan tray.
Airflow
28 CFM (low speed)
44 CFM (high speed)