D-Link DES-3010F Reference Manual - Page 26

Switch Port Commands - d link manual

Page 26 highlights

DES-30XX Layer 2 Switch CLI Reference Manual 5 SWITCH PORT COMMANDS The switch port commands in the Command Line Interface (CLI) are listed (along with the appropriate parameters) in the following table. Command config ports show ports Parameters config ports [ | all] {speed [auto | 10_half | 10_full | 100_half | 100_full | {1000_full {[master | slave]}}] | flow_control [enable | disable] | state [enable | disable] | description [ | clear_description]} {} {[description | err_disabled]} Each command is listed, in detail, in the following sections. config ports Purpose Syntax Description Parameters Used to configure the Switch's Ethernet port settings. config ports [ | all] {speed [auto | 10_half | 10_full | 100_half | 100_full | {1000_full {[master | slave]}}] | flow_control [enable | disable] | state [enable | disable] | description [ | clear_description]} This command allows for the configuration of the Switch's Ethernet ports. Only the ports listed in the will be affected. − Specifies a port or range of ports to be configured. all − Configure all ports on the Switch. speed - Allows the user to set the speed of a port or range of ports, with the addition of one of the following: auto − Enables auto-negotiation for the specified range of ports. [10 | 100 | 1000] − Configures the speed in Mbps for the specified range of ports. Gigabit ports are statically set to 1000 and cannot be set to slower speeds. [half | full] − Configures the specified range of ports as either fullor half-duplex. [master | slave] - The master and slave parameters refer to connections running a 1000BASE-T cable for connection between the Switch port and other device capable of a gigabit connection. The master setting will allow the port to advertise capabilities related to duplex, speed and physical layer type. The master setting will also determine the master and slave relationship between the two connected physical layers. This relationship is necessary for establishing the timing control between the two physical layers. The timing control is set on a master physical layer by a local source. The slave setting uses loop timing, where the timing comes form a data stream received from the master. If one connection is set for 1000 master, the other side of the connection must be set for 1000 slave. Any other configuration will result in a link down status for both ports. flow_control [enable | disable] - Enable or disable flow control for the specified ports. 22

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174

DES-30XX Layer 2 Switch CLI Reference Manual
22
5
S
WITCH
P
ORT
C
OMMANDS
The switch port commands in the Command Line Interface (CLI) are listed (along with the appropriate parameters) in the
following table.
Command
Parameters
config ports
config ports [<portlist> | all] {speed [auto | 10_half | 10_full |
100_half | 100_full | {1000_full {[master | slave]}}] | flow_control
[enable | disable] | state [enable | disable] | description [<desc 1-
32> | clear_description]}
show ports
{<portlist>} {[description | err_disabled]}
Each command is listed, in detail, in the following sections.
config ports
Purpose
Used to configure the Switch’s Ethernet port settings.
Syntax
config ports [<portlist> | all] {speed [auto | 10_half | 10_full | 100_half
| 100_full | {1000_full {[master | slave]}}] | flow_control [enable |
disable] | state [enable | disable] | description [<desc 1-32> |
clear_description]}
Description
This command allows for the configuration of the Switch’s Ethernet ports.
Only the ports listed in the
<portlist>
will be affected.
Parameters
<portlist>
Specifies a port or range of ports to be configured.
all
Configure all ports on the Switch.
speed
– Allows the user to set the speed of a port or range of ports, with
the addition of one of the following:
±
auto
Enables auto-negotiation for the specified range of ports.
±
[10 | 100 | 1000]
Configures the speed in Mbps for the specified
range of ports. Gigabit ports are statically set to 1000 and cannot be
set to slower speeds.
±
[half | full]
Configures the specified range of ports as either full-
or half-duplex.
[master | slave]
– The
master
and
slave
parameters refer to connections
running a 1000BASE-T cable for connection between the Switch port and
other device capable of a gigabit connection. The
master
setting will allow
the port to advertise capabilities related to duplex, speed and physical
layer type. The
master
setting will also determine the master and slave
relationship between the two connected physical layers. This relationship
is necessary for establishing the timing control between the two physical
layers. The timing control is set on a
master
physical layer by a local
source. The
slave
setting uses loop timing, where the timing comes form
a data stream received from the
master
. If one connection is set for
1000
master
, the other side of the connection must be set for
1000 slave
. Any
other configuration will result in a link down status for both ports.
flow_control [enable | disable]
– Enable or disable flow control for the
specified ports.