HP Integrity rx2800 Smart Setup Scripting Toolkit Administrator's Guide 4.0 - Page 47

Table 6-2 hpacuscripting Warning Codes, Table 6-3 hpacuscripting Error Codes

Page 47 highlights

Table 6-2 hpacuscripting Warning Codes (continued) Warning Code Message Reason 4003 One or more controller Certain commands require that the controller be configured commands were skipped because before they can be sent to the controller. the controller is not configured 4004 Using Repeat function Some commands have been ignored because the Repeat parameter has been specified in the input file. Table 6-3 hpacuscripting Error Codes Warning Code 0 2053 2056 2059 2064 2817 2818 2819 2819 2821 2823 2824 2825 2826 2827 2828 2829 Message Reason - No error exists. The program completed successfully. Too many coinciding expansion, migration, or extension operations The new configuration requires more transformations than are possible at one time. For example, you cannot expand a logical volume and transform its RAID level at the same time. Controller does not support The controller does not support license key entry or deletion. license keys Invalid license key The entered license key is not a valid license key. Controller does not support The controller does not support SSP functions. SSP Invalid action The requested actions are invalid, for example, combining -reset with capture mode. Invalid Method The method must be either Custom or Auto. Controller '%s' is invalid The controller specified is not specified correctly. Invalid Controller An invalid controller value was specified. No controllers detected No controllers were detected. This error applies to Input mode only. Invalid Rebuild Priority The specified rebuild priority is not supported. Invalid Expand Priority The specified expand priority is not supported. This error also occurs if the controller does not allow expansion (does not support Expand Priority). Invalid Array The array ID is invalid. Array not specified The Array command is missing from the script file. Some commands were found that require an array to be specified. New Array ID does not match The array ID in the script file does not match the array ID of the the next available Array ID next available array. For example, if the configuration has Array A and the input file specifies Array C (without Array B), the script generates this error. New Array ID already exists When running in Configure mode, the array ID in the script file already exists in the configuration. Configure mode can only create new arrays. Cannot create Array The controller does not allow a new array to be created. Possible causes are there are no unassigned physical drives on the controller or the maximum number of arrays or logical drives has already been reached. hpacuscripting 47

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65

Table 6-2 hpacuscripting Warning Codes
(continued)
Reason
Message
Warning
Code
Certain commands require that the controller be configured
before they can be sent to the controller.
One or more controller
commands were skipped because
the controller is not
configured
4003
Some commands have been ignored because the
Repeat
parameter
has been specified in the input file.
Using Repeat function
4004
Table 6-3 hpacuscripting Error Codes
Reason
Message
Warning
Code
No error exists. The program completed successfully.
0
The new configuration requires more transformations than are
possible at one time. For example, you cannot expand a logical
volume and transform its RAID level at the same time.
Too many coinciding
expansion, migration, or
extension operations
2053
The controller does not support license key entry or deletion.
Controller does not support
license keys
2056
The entered license key is not a valid license key.
Invalid license key
2059
The controller does not support SSP functions.
Controller does not support
SSP
2064
The requested actions are invalid, for example, combining
-reset
with capture mode.
Invalid action
2817
The method must be either Custom or Auto.
Invalid Method
2818
The controller specified is not specified correctly.
Controller '%s' is invalid
2819
An invalid controller value was specified.
Invalid Controller
2819
No controllers were detected. This error applies to Input mode
only.
No controllers detected
2821
The specified rebuild priority is not supported.
Invalid Rebuild Priority
2823
The specified expand priority is not supported. This error also
occurs if the controller does not allow expansion (does not
support Expand Priority).
Invalid Expand Priority
2824
The array ID is invalid.
Invalid Array
2825
The Array command is missing from the script file. Some
commands were found that require an array to be specified.
Array not specified
2826
The array ID in the script file does not match the array ID of the
next available array. For example, if the configuration has Array
A and the input file specifies Array C (without Array B), the
script generates this error.
New Array ID does not match
the next available Array ID
2827
When running in Configure mode, the array ID in the script file
already exists in the configuration. Configure mode can only
create new arrays.
New Array ID already exists
2828
The controller does not allow a new array to be created. Possible
causes are there are no unassigned physical drives on the
controller or the maximum number of arrays or logical drives
has already been reached.
Cannot create Array
2829
hpacuscripting
47