HP Integrity rx2800 Smart Setup Scripting Toolkit Administrator's Guide 4.0 - Page 48

Table 6-3 hpacuscripting Error Codes

Page 48 highlights

Table 6-3 hpacuscripting Error Codes (continued) Warning Code 2830 2831 2832 2833 2834 2836 Message Reason Cannot expand Array The array cannot be expanded. Possible causes are the controller has no unassigned physical drives attached or the maximum number of arrays or logical drives has been reached already. Cannot change Array Spare The spare state of the array cannot be changed. This can happen when adding a spare or dropping a spare, and the current configuration does not allow a spare state change for the array. Invalid physical drive The specified physical drive is not a valid physical drive, or it cannot be placed in the array. Invalid Spare The specified spare drive is not a valid spare drive, or it cannot be placed on the array as a spare. Invalid logical drive The logical drive ID is not valid. New Logical Drive ID does The script file specifies a logical drive ID that is not the first not match the next available unused ID in the sequence. For example, if the controller has Logical Drive ID only Logical Drive 1 and the script file attempts to create Logical If you are attempting to Drive 3 (without Logical Drive 2), the script generates this error. replicate a configuration This error can occur when using an input file with logical drive that has non-consecutive logical drive numbers, then you must change the script numbers that are not sequential. In this case, you must change the logical drive numbers so that they are sequential in the input file. file so that the logical drive numbers are consecutive. 2837 2838 2839 2841 2842 2843 2844 2849 2850 2851 2852 New Logical Drive ID already When running in Configure mode, this error occurs when the exists Logical Drive ID in the script file already exists in the configuration. Configure mode can only create new logical drives. Cannot create Logical Drive The array has no free space, or the maximum number of logical drives has already been reached. Cannot migrate Logical Drive The controller does not support RAID migration, or the current RAID controller configuration does not allow migration to occur. Cannot extend Logical Drive The controller does not support extension, or the current controller configuration cannot be extended. For example, extension is not possible if the array has no free space. Invalid RAID The specified RAID is invalid or is not possible with the current physical disk and aarray configuration. Invalid Size The specified size is invalid or is not possible with the current configuration. Invalid Stripe Size The specified stripe size is invalid, not supported with the current RAID level, or not supported with the current configuration. Invalid The valid parameters are Yes and No (default). ClearConfigurationWithDataLoss parameter Controller does not support The controller does not support setting a chassis name. Chassis Name Invalid Chassis Name The entered chassis name is invalid. The chassis name can only consist of the following characters: a-z, A-Z, 0-9 and [space]. It cannot end with a space character or exceed the maximum number of characters allowed by the controller. Invalid SSP State The requested SSP state is not a valid SSP state. 48 Utilities reference

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65

Table 6-3 hpacuscripting Error Codes
(continued)
Reason
Message
Warning
Code
The array cannot be expanded. Possible causes are the controller
has no unassigned physical drives attached or the maximum
number of arrays or logical drives has been reached already.
Cannot expand Array
2830
The spare state of the array cannot be changed. This can happen
when adding a spare or dropping a spare, and the current
configuration does not allow a spare state change for the array.
Cannot change Array Spare
2831
The specified physical drive is not a valid physical drive, or it
cannot be placed in the array.
Invalid physical drive
2832
The specified spare drive is not a valid spare drive, or it cannot
be placed on the array as a spare.
Invalid Spare
2833
The logical drive ID is not valid.
Invalid logical drive
2834
The script file specifies a logical drive ID that is not the first
unused ID in the sequence. For example, if the controller has
only Logical Drive 1 and the script file attempts to create Logical
Drive 3 (without Logical Drive 2), the script generates this error.
This error can occur when using an input file with logical drive
numbers that are not sequential. In this case, you must change
the logical drive numbers so that they are sequential in the input
file.
New Logical Drive ID does
not match the next available
Logical Drive ID
If you are attempting to
replicate a configuration
that has non-consecutive
logical drive numbers, then
you must change the script
file so that the logical
drive numbers are
consecutive.
2836
When running in Configure mode, this error occurs when the
Logical Drive ID in the script file already exists in the
configuration. Configure mode can only create new logical drives.
New Logical Drive ID already
exists
2837
The array has no free space, or the maximum number of logical
drives has already been reached.
Cannot create Logical Drive
2838
The controller does not support RAID migration, or the current
controller configuration does not allow migration to occur.
Cannot migrate Logical Drive
RAID
2839
The controller does not support extension, or the current
controller configuration cannot be extended. For example,
extension is not possible if the array has no free space.
Cannot extend Logical Drive
2841
The specified RAID is invalid or is not possible with the current
physical disk and aarray configuration.
Invalid RAID
2842
The specified size is invalid or is not possible with the current
configuration.
Invalid Size
2843
The specified stripe size is invalid, not supported with the current
RAID level, or not supported with the current configuration.
Invalid Stripe Size
2844
The valid parameters are Yes and No (default).
Invalid
ClearConfigurationWithDataLoss
parameter
2849
The controller does not support setting a chassis name.
Controller does not support
Chassis Name
2850
The entered chassis name is invalid. The chassis name can only
consist of the following characters: a-z, A-Z, 0-9, !, @, #, *, ( , ) , ,,
- , _, +, :, ., /, and [space]. It cannot end with a space character or
exceed the maximum number of characters allowed by the
controller.
Invalid Chassis Name
2851
The requested SSP state is not a valid SSP state.
Invalid SSP State
2852
48