HP StorageWorks MSA1510i HP StorageWorks 1510i Modular Smart Array installatio - Page 114
Cache Data Lost, Data Found
![]() |
View all HP StorageWorks MSA1510i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 114 highlights
Message Type 54 REDUNDANCY FAILED CACHE DIMMS Error MISMATCH 57 REMOVE OTHER CONTROLLER NOW 60 NO CACHE MODULE FOUND Error 61 DUAL CACHE MODULE SIZE MISMATCH Error 62 CACHE MODULE # MB 63 VALID CACHE DATA FOUND AT POWER-UP Informational Informational 64 CACHE DATA LOST BATTERY DEAD Error 65 CACHE HARDWARE ENABLED Informational Description Action The cache memory modules on the two controllers are not the same size. All cache memory modules must be the same size for redundancy to operate. Remove the array controller that has been halted, replace the cache modules with the appropriately sized ones, wait 10 seconds, and then reinsert the array controller, ensuring that it is fully seated in the chassis. In dual-controller configurations, the firmware has determined that the other controller has been disabled and can safely be removed. Remove the other array controller for the planned service. When complete, reinsert the array controller, ensuring that it is fully seated in the chassis. The array controller requires at least one cache module in order to operate. Either there is not one present or it has failed. Remove the failed array controller, either add a cache module or replace the failed one, wait 10 seconds, and then reinsert it, ensuring that it is fully seated in the chassis. If the issue persists, contact HP support. The array controller has two cache modules attached but they are of different sizes. Both cache modules must be the same size. Remove the failed array controller, replace one of the cache modules with a different one that is of the correct size, wait 10 seconds, and then reinsert it, ensuring that it is fully seated in the chassis. The size of the cache module inserted into the indicated cache module slot. Valid host data was found in the battery backed cache memory at power up. This data has been flushed to the drives. The battery on the cache memory was no longer charged. If there was data in the cache memory, it is lost. The cache hardware had been temporarily disabled but is now enabled again. This may have been due to insufficient charge on the batteries that are now charged to capacity. 114 MSA controller LCD panel message descriptions
![](/manual_guide/products/hewlettpackard-storageworks-1510i-hp-storageworks-1510i-modular-smart-array-installation-user-guide-383070002-2008-1efa5c4/114.png)