HP StorageWorks MSA1510i HP StorageWorks 1510i Modular Smart Array installatio - Page 119
State Wrong Drive, State Deleted
View all HP StorageWorks MSA1510i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 119 highlights
Message Type 108 VOLUME # STATE MISSING DRIVES Error 109 VOLUME # STATE WRONG DRIVE REPLACED Error 110 VOLUME # EXPANSION DISABLED Informational 111 VOLUME # INITIALIZING PARITY Informational 112 VOLUME # REBUILD FAILURE Error 113 VOLUME # EXPANSION FAILURE Error 114 VOLUME # STATE DELETED Informational 115 VOLUME # MEDIA EXCHANGED Informational 120 CONFIGURED VOLUMES Informational Description Action The configured volume is missing too many of the SCSI hard drives that it is composed of, making it unusable. The volume is disabled. Power off the MSA and then all attached storage enclosures. Unplug and reinsert all SCSI hard drives ensuring they are fully seated in their bays. Check the cables connecting the MSA to any attached storage enclosures. Power on the attached enclosures and then the MSA. The configured volume appears to have had known, good SCSI drives replaced instead of known, failed drives. Power off the MSA. Restore the good drives and replace the failed drives. The volume expansion operation on the configured volume has been disabled. This may be because a rebuild operation is ongoing, another expansion is already running, or the cache memory is disabled due to a low battery. The expansion will start after the condition has been cleared. The array controller is calculating and storing parity information for the configured volume and therefore performance may be lower until it completes. The rebuild operation on the configured volume has failed. If the volume is still operating in regenerative mode, remove the new SCSI drive that was added as a replacement for the original failed drive and replace it with a different new drive. The volume expansion operation on the configured volume has failed. Open the HP Storage Management Utility or MSA-CLI and use it to determine the state of the volume. If the volume is still operational, then it is possible to retry the operation. The configured volume has been deleted and is no longer available. Volumes are deleted by using the HP Storage Management Utility or MSA-CLI. All failed hard drives of the specified volume have been replaced by good hard drives or all unplugged hard drives in the volume have been plugged back in. This message should be followed by message 02 ENABLE VOLUME ? ''=YES. See the entry for 02 ENABLE VOLUME ? ''=YES. The specified number of configured volumes were detected at power up. 1510i Modular Smart Array installation and user guide 119