Page 125 highlights
Message Type 406 STORAGE BOX # OVERHEATING Error 407 STORAGE BOX # OVERHEATED Error 408 STORAGE BOX # POWER SUPPLY OK Informational 409 STORAGE BOX # POWER SUPPLY FAILED 410 STORAGE BOX # POWER SUPPLY ADDED 411 STORAGE BOX # POWER SUPPLY REMOVED Error Informational Informational 412 STORAGE BOX # EMU NOT RESPONDING Error 413 STORAGE BOX # EMU VERSION Informational 414 STORAGE BOX HOT REMOVED 415 STORAGE BOX HOT ADDED Informational Informational Description The temperature in the specified storage enclosure is starting to exceed the normal operating range. The temperature in the specified storage enclosure has exceeded the safe operating range. The power supply in the specified storage enclosure that was previously marked as failed or degraded is now operating normally. A power supply in the specified storage enclosure has failed. Action Check all fans and ensure they are operating. Any failed fans should be replaced. Ensure that there is a module or blanking panel (cover plate) in all MSA chassis bays and slots. Empty bays affect the airflow and cooling ability of the MSA. The MSA should be powered off as soon as possible and immediately after that, the enclosure should be powered off, to avoid hardware failure. Check all MSA fans and ensure they are operating. Any failed fan should be replaced. Ensure that there is a module or blanking panel (cover plate) in all MSA chassis bays and slots. Empty bays affect the airflow and cooling ability of the MSA. Check all power supplies to ensure they are operating. Replace any failed power supplies. A power supply in the specified storage enclosure has been added. A power supply in the specified storage enclosure has been removed. An EMU in the specified storage enclosure is not responding to commands. Make sure the storage box is powered on. Ensure all cables are connected securely. Power off the MSA and the storage enclosure. Then reapply power to the storage box and then the MSA. If the issue persists, contact HP support. The version of firmware running on the EMU. This is only displayed for the internal EMU of the MSA chassis. It is not displayed for externally connected storage boxes. An external storage enclosure has been hot removed from the back of the MSA. An external storage enclosure has been hot added to the back of the MSA. 1510i Modular Smart Array installation and user guide 125