HP StorageWorks MSA1510i HP StorageWorks 1510i Modular Smart Array installatio - Page 91
Recovering corrupted MSA controller firmware, Flow control: None
View all HP StorageWorks MSA1510i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 91 highlights
Recovering corrupted MSA controller firmware If the controller detects a firmware corruption, the following message is displayed on the LCD panel: ERROR: ROM CORRUPT SEND IMG VIA XMODEM To recover the controller, you must obtain a current firmware image and send it to the controller using a serial connection. 1. Go to the MSA1510i support website and obtain the latest controller firmware. NOTE: If you are not yet registered, select the option to receive e-mail notifications, advisories, and support alerts about MSA system hardware, firmware, drivers, and software components. This alert notification system is a one-way broadcasting method used to distribute important notices about HP products. Information about your MSA is not requested when subscribing to this service. 2. Establish a serial connection to the affected controller: • Use the custom CLI configuration cable shipped with the MSA. • Use a terminal emulator program that supports the Xmodem protocol, such as HyperTerminal. • Use the following emulator connection settings: • Bits per second: 19200 • Data bits: 8 • Parity: None • Stop bits: 1 • Flow control: None A blank emulator window is displayed-no CLI prompt is displayed. 1510i Modular Smart Array installation and user guide 91