HP StorageWorks MSA1510i HP StorageWorks 1510i Modular Smart Array installatio - Page 122

Recovery Rom, Autoflash Done, Autoflash Failed, Rom Cloning, Started, Failed, Firmware Flash

Page 122 highlights

Message Type 301 RECOVERY ROM AUTOFLASH DONE Informational 302 RECOVERY ROM AUTOFLASH FAILED Error 303 ROM CLONING STARTED Informational 304 ROM CLONING DONE Informational 305 ROM CLONING FAILED Error 306 FIRMWARE FLASH STARTED Informational Description Action The array controller has successfully completed the process of copying the current active firmware image into the backup recovery ROM. The array controller failed to copy the current active firmware image into the backup recovery ROM. Recovery ROM support is disabled. Remove the failing array controller, wait 10 seconds, and then reinsert the array controller, ensuring that it is fully seated in the chassis. The ROM autoflash process is attempted again. Should the issue persist, contact HP support. Indicates that the two array controllers in the MSA do not have the same version of firmware on them. Therefore, one array controller's version of the firmware is copied on to the other array controller. Both controllers must be running the same version of firmware in order for controller redundancy to operate. If both array controllers are in the power-on sequence, the most recent version of firmware is used. If one array controller has already completed the power-on sequence and is now active, its version of firmware is used even if less recent. In dual-controller MSA only, this indicates that the two array controllers in an MSA have finished copying one array controller's version of firmware to the other array controller. Both controllers must be running the same version of firmware in order for controller redundancy to operate. In dual-controller MSA only, this indicates that the two array controllers in an MSA failed to copy one array controller's version of firmware to the other array controller. Both controllers must be running the same version of firmware in order for controller redundancy to operate. Remove the standby array controller, wait 10 seconds, and then reinsert the array controller ensuring that it is fully seated in the chassis. The ROM cloning process is attempted again. If the issue persists, contact HP support. The array controller in the MSA has started the firmware flash process. Do not turn off power to the system until it has completed. This could take several minutes. 122 MSA controller LCD panel message descriptions

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160

Message
Type
Description
Action
301 RECOVERY ROM
AUTOFLASH DONE
Informational
The array controller has successfully
completed the process of copying
the current active
rmware image
into the backup recovery ROM.
302 RECOVERY ROM
AUTOFLASH FAILED
Error
The array controller failed to copy
the current active
rmware image
into the backup recovery ROM.
Recovery ROM support is disabled.
Remove the failing array controller,
wait 10 seconds, and then reinsert
the array controller, ensuring that
it is fully seated in the chassis.
The ROM auto
ash process is
attempted again.
Should the issue persist, contact
HP support.
303 ROM CLONING
STARTED
Informational
Indicates that the two array
controllers in the MSA do not
have the same version of
rmware
on them. Therefore, one array
controller's version of the
rmware
is copied on to the other array
controller. Both controllers must
be running the same version of
rmware in order for controller
redundancy to operate. If both
array controllers are in the
power-on sequence, the most
recent version of
rmware is used.
If one array controller has already
completed the power-on sequence
and is now active, its version of
rmware is used even if less recent.
304 ROM CLONING
DONE
Informational
In dual-controller MSA only,
this indicates that the two array
controllers in an MSA have
nished
copying one array controller's
version of
rmware to the other
array controller. Both controllers
must be running the same version
of
rmware in order for controller
redundancy to operate.
305 ROM CLONING
FAILED
Error
In dual-controller MSA only,
this indicates that the two array
controllers in an MSA failed to
copy one array controller's version
of
rmware to the other array
controller. Both controllers must
be running the same version of
rmware in order for controller
redundancy to operate.
Remove the
standby
array
controller, wait 10 seconds, and
then reinsert the array controller
ensuring that it is fully seated in the
chassis. The ROM cloning process
is attempted again.
If the issue persists, contact HP
support.
306 FIRMWARE FLASH
STARTED
Informational
The array controller in the MSA has
started the
rmware
ash process.
Do not turn off power to the system
until it has completed. This could
take several minutes.
122
MSA controller LCD panel message descriptions