HP StorageWorks MSA1510i HP StorageWorks 1510i Modular Smart Array installatio - Page 122
Recovery Rom, Autoflash Done, Autoflash Failed, Rom Cloning, Started, Failed, Firmware Flash
![]() |
View all HP StorageWorks MSA1510i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 122 highlights
Message Type 301 RECOVERY ROM AUTOFLASH DONE Informational 302 RECOVERY ROM AUTOFLASH FAILED Error 303 ROM CLONING STARTED Informational 304 ROM CLONING DONE Informational 305 ROM CLONING FAILED Error 306 FIRMWARE FLASH STARTED Informational Description Action The array controller has successfully completed the process of copying the current active firmware image into the backup recovery ROM. The array controller failed to copy the current active firmware image into the backup recovery ROM. Recovery ROM support is disabled. Remove the failing array controller, wait 10 seconds, and then reinsert the array controller, ensuring that it is fully seated in the chassis. The ROM autoflash process is attempted again. Should the issue persist, contact HP support. Indicates that the two array controllers in the MSA do not have the same version of firmware on them. Therefore, one array controller's version of the firmware is copied on to the other array controller. Both controllers must be running the same version of firmware in order for controller redundancy to operate. If both array controllers are in the power-on sequence, the most recent version of firmware is used. If one array controller has already completed the power-on sequence and is now active, its version of firmware is used even if less recent. In dual-controller MSA only, this indicates that the two array controllers in an MSA have finished copying one array controller's version of firmware to the other array controller. Both controllers must be running the same version of firmware in order for controller redundancy to operate. In dual-controller MSA only, this indicates that the two array controllers in an MSA failed to copy one array controller's version of firmware to the other array controller. Both controllers must be running the same version of firmware in order for controller redundancy to operate. Remove the standby array controller, wait 10 seconds, and then reinsert the array controller ensuring that it is fully seated in the chassis. The ROM cloning process is attempted again. If the issue persists, contact HP support. The array controller in the MSA has started the firmware flash process. Do not turn off power to the system until it has completed. This could take several minutes. 122 MSA controller LCD panel message descriptions
![](/manual_guide/products/hewlettpackard-storageworks-1510i-hp-storageworks-1510i-modular-smart-array-installation-user-guide-383070002-2008-1efa5c4/122.png)