Chapter 9 Specifications Power Ratings Table 9-7 displays the HP Server tc4100 power ratings. Table 9-7. Power Ratings AC Input Voltages 100 VAC 120 VAC 208 VAC Maximum Input Power (VA) 650 640 625 230/240 VAC 630 Maximum Input Power (W) 643 628 605 603 Power Supply Table 9-8 displays the HP Server tc4100 power requirements. Table 9-8. Power Supply Recommended (Single Unit) Input Type Input Voltage and Frequency Power Availability Maximum Cold Inrush Current per Power Cord Wide Range, PFC 100-127VAC±10%;50/60Hz 200-240VAC±10%;50/60Hz 425 W continuous 8 AMPs @ 120 VAC for

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130

125
Chapter 9
Specifications
Power Ratings
Table 9-7
displays the HP Server tc4100 power ratings.
Power Supply
Table 9-8
displays the HP Server tc4100 power requirements.
The power cord set found in your shipping box has been approved for use in the country where the Server was
purchased. If any other power cord set is used, it must meet appropriate safety requirements in the country in
which the Server is to be used.
Table 9-7.
Power Ratings
AC Input Voltages
Maximum Input
Power (VA)
Maximum Input
Power (W)
Maximum Operating
Current RMS (AMPS)
100 VAC
650
643
6.5
120 VAC
640
628
5.3
208 VAC
625
605
3.0
230/240 VAC
630
603
2.6
Table 9-8.
Power Supply Recommended (Single Unit)
Input Type
Wide Range, PFC
Input Voltage and
Frequency
100-127VACĀ±10%;50/60Hz
200-240VACĀ±10%;50/60Hz
Power Availability
425 W continuous
Maximum Cold Inrush
Current per Power Cord
8 AMPs @ 120 VAC for <10ms
16 AMPs @ 240 VAC for <10ms
Table 9-9.
General Cord Set Requirements
Cord Set
Approved or recognized by
a safety agency in the
country of use)
250 VAC, 10 A
125 VAC, 10 A
Maximum Length
2.4 m (8 ft)