HP Tc4100 hp server tc4100 operation and maintenance guide (English, 2.1) - Page 13
Table 1-3., Using the Internal Diagnostic Panel, LED Name, Error Conditions, Corrective Action - memory type
View all HP Tc4100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
Chapter 1 Control and Indicators Table 1-3 describes how to troubleshoot and solve issues using the Internal Diagnostic Panel Table 1-3. Using the Internal Diagnostic Panel LED Name Error Conditions Corrective Action Processor Temperature over threshold, Internal CPU Error 1. Check the system event log to view error details. If CPU is over the temperature threshold, verify that the heat sink and thermal grease are installed properly--call HP Customer Care. Also check items in the System Temperature section below. 2. If errors are not resolved, try rebooting the server to resolve the error. Memory DIMM ECC double and single bit errors 1. Check the system event log to view error details. If the error is a predictive failure, you may continue to operate the Server, however, the DIMM should be replaced as soon as possible to avoid unscheduled downtime. If the error is a double-bit uncorrectable error, the DIMM should be replaced immediately. 2. If other errors occur, power down the server, unplug the server from its power source, re-seat the DIMM, and restart the HP Server tc4100. System Fan Incorrect fan speed, predictive fan failure, fan failure 1. Reseat system fan module. 2. If the error is not resolved, replace the system fans. System Board System board Reboot the HP Server tc4100. voltage level error Memory Incorrect memory Check that the installed memory is HP PC133 ECC SDRAM memory. Configuration type If this is not correct, replace all DIMMs that are not HP PC133 ECC SDRAM memory. Processor Incompatible Configuration Stepping Check the stepping of the processors. Replace any processors that do not have compatible steppings. System Temperature over Check the following: Temperature threshold • All system fans are operational • CPU heat sink is installed correctly on processor with thermal grease--call HP Customer Care. • Room temperature within supported temperature range. See Chapter 9 for Environmental Requirements. • All covers, filler panels and air ducts are installed correctly. • Adequate ventilation • Check system event log for further details If none of the above steps resolves the problem, reboot HP Server tc4100. Check Event Many errors Log Check the system event log to view error conditions. The system event log can be accessed from: • Instant Toptools • Toptools • Navigator CD • Diagtools 11