HP Xw8200 HP Workstation xw8200 Service and Technical Reference Guide (Complet - Page 116
Table 5-4, Power Supply Problems Continued
UPC - 882780210455
View all HP Xw8200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 116 highlights
Table 5-4 Power Supply Problems (Continued) Problem Cause Solution Power LED flashes Red, once every two seconds. Power failure (power supply is 1 Check if a device is causing the problem by removing overloaded). ALL attached devices). Power on the system. If the system enters the POST, then power off and replace one device at a time and repeat this procedure until failure occurs. Replace the device causing the failure. Continue adding devices one at a time to ensure all devices are functioning properly. 2 Check the power supply functionality. a Disconnect AC power. b Remove all internal power supply cables from the system board. c Plug in AC power. z If the power supply fan spins and the BIST LED lights, then the power supply is good. Replace the system board. z If the power supply fan does not spin or the BIST LED does not light, replace the power supply. 116 SYSTEM DIAGNOSTICS AND TROUBLESHOOTING