Page 72 highlights
2 Rotate the front bezel away 2 from the chassis and remove the bezel. 1 2 Bezel Blanks To remove the bezel blanks: 1 Disconnect power from the system (page 66) and remove the front bezel (page 71). 2 Remove the bezel blanks by squeezing in on the tabs and pushing the bezel blanks out. Hood Sensor (Smart Cover Sensor) To remove the hood sensor: 1 Disconnect power from the system (page 66), remove the access panel (page 71), and lay the workstation on its side with the system board facing up. 2 Disconnect the white 1x3 hood sensor connector from the inline connector attached to the front panel harness. 3 Slide the hood sensor forward. 72 REMOVAL AND REPLACEMENT PROCEDURES
![](/manual_guide/products/hewlettpackard-xw8200-hp-workstation-xw8200-service-technical-reference-guide-completeversion-c8fb774/72.png)
72
REMOVAL AND REPLACEMENT PROCEDURES
2
Rotate the front bezel away
2
from the chassis and remove the bezel.
Bezel Blanks
To remove the bezel blanks:
1
Disconnect power from the system (
page 66
) and remove the front bezel (
page 71
).
2
Remove the bezel blanks by squeezing in on the tabs and pushing the bezel blanks out.
Hood Sensor (Smart Cover Sensor)
To remove the hood sensor:
1
Disconnect power from the system (
page 66
), remove the access panel (
page 71
), and lay the
workstation on its side with the system board facing up.
2
Disconnect the white 1x3 hood sensor connector from the inline connector attached to the front panel
harness.
3
Slide the hood sensor forward.
1
2