when using Windows NT 4.0 Service Pack 4., Run Computer Setup F10 Setup. - workstation gaming
UPC - 882780210455
View all HP Xw8200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 138 highlights
Table 5-18 POST Error Messages (Continued) Screen Message Probable Cause Recommended Action 1203-Game Port Address Conflict Detected Device IRQ address conflicts with another device. Reset the IRQ 1720 SMART Hard Drive Detect Imminent Failure Hard drive is about to fail. (Some hard 1 drives have a firmware patch that will fix an erroneous error message.) Determine if hard drive is giving correct error message. Run the Drive Protection System test if applicable. 2 Apply firmware patch if applicable (see http:// www.hp.com/support). 3 Back up contents and replace hard drive. 1721-SMART SCSI Hard Drive detects imminent failure Hard drive is about to fail. (Some hard 1 drives have a firmware patch that will fix an erroneous error message.) Determine if hard drive is giving correct error message. Run the Drive Protection System test if applicable. 2 Apply firmware patch if applicable (see http:// www.hp.com/support). 3 Back up contents and replace hard drive. 1780-Disk 0 Failure The drive is not installed correctly or has failed. 1 Make sure that any jumpers are set correctly, and that power and drive cables are connected, both to the drive and the system board. 2 Verify that the cables are the correct cables for your computer model. If this message persists, you may need service for your workstation. 1781-Disk 1 Failure The drive is not installed correctly or has failed. 1 Make sure that any jumpers are set correctly, and that power and drive cables are connected, both to the drive and the system board. 2 Verify that the cables are the correct cables for your computer model. If this message persists, you may need service for your workstation. 1782-Disk Controller Failure Hard drive circuitry error. 1 Run Computer Setup (F10 Setup). 2 Clear CMOS. 3 Check cable seating/jumper settings. 4 Run hard drive diagnostics. 5 Disconnect additional drives. 6 Run the Drive Protection System test if available. 7 Check http://www.hp.com\support\ techpubs\customer_advisories for possible changes when using Windows NT 4.0 Service Pack 4. 8 Replace the hard drive. 9 Replace the system board. 1785-Multibay incorrectly installed No other IDE device may be attached Attach the Multibay as device 0 on the secondary IDE to the same IDE controller. controller. 138 SYSTEM DIAGNOSTICS AND TROUBLESHOOTING