HP Xw8400 HP xw8400 Service and Technical Reference Guide - Page 141
SATA Emulation, Combined IDE Controller, Storage>Storage Options, Separate IDE Controller - gaming
UPC - 883585271085
View all HP Xw8400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 141 highlights
Table 5-18 POST error messages (continued) Screen Message Probable Cause Recommended Action 1155-Serial Port Address Conflict Detected. Both external and internal serial ports 1. are assigned to same IRQ. 2. Remove any COM port expansion cards. Clear CMOS. 3. Reconfigure card resources and run Computer Setup (F10 Setup). 4. Run Computer Setup or Windows utilities. 1201-System Audio Address Conflict Detected. Device IRQ address conflicts with another device. (Usually due to an add-in audio card.) Reset the IRQ. 1202-MIDI Port Address Conflict Detected. Device IRQ address conflicts with another device. (Usually due to an add-in audio card.) Reset the IRQ. 1203-Game Port Address Conflict Detected. Device IRQ address conflicts with another device. (Usually due to an add-in audio card.) Reset the IRQ. 1720 SMART Hard Drive Detect Imminent Failure. Hard drive is about to fail. (Some hard 1. drives have a firmware patch that will fix an erroneous error message.) 2. Determine if hard drive is giving correct error message. Run the Drive Protection System test if applicable. 3. Apply firmware patch if applicable (see http://www.hp.com/support). 4. Back up contents and replace hard drive. 1783-Disk 0 Failure. The drive is not installed correctly or 1. Be sure that power and drive cables are connected has failed. to the drive and to the system board. 2. Verify that the cables are the correct cables for your computer model. 3. If this message persists, you might need service for your workstation. 1784-Disk 1 Failure. The drive is not installed correctly or 1. Be sure that power and drive cables are connected has failed. to the drive and to the system board. 2. Verify that the cables are the correct cables for your computer model. If this message persists, you might need service for your workstation. 1794-Inaccessible devices attached to SATA 1 and/or SATA 3. Devices attached to the SATA 1 (blue) 1. and SATA 3 (black) connectors are inaccessible while SATA Emulation is 2. set to Combined IDE Controller in Setup. Run Computer Setup (F10 Setup). Select Storage>Storage Options, and set the SATA controller to Separate IDE Controller. 1800-Temperature Alert. Internal temperature exceeds specification. 1. Check that workstation air vents are not blocked and that the cooling fan is running. 2. Verify processor speed selection. 3. Replace the processor. 4. Replace the system board. ENWW POST error messages 131