Hitachi HDS728080PLAT20 Specifications - Page 112

Not Sequential bit, Read Continuous bit, Write Continuous bit, Handle Streaming Error bit, Streaming

Page 112 highlights

10.17.4 Not Sequential bit The Not Sequential bit specifies that the next read stream command with the same Stream ID may not be sequential in LBA space. This information helps the device with pre-fetching decisions. 10.17.5 Read Continuous bit If the Read Continuous bit is set to one for the command, the device shall transfer the requested amount of data to the host within the Command Completion Time Limit even if an error occurs. The data sent to the host by the device in an error condition is vendor specific. 10.17.6 Write Continuous bit If the Write Continuous bit is set to one for the command, and an error is encountered, the device shall complete the request without posting an error. If an error cannot be resolved within the Command Completion Time Limit, the erroneous section on the media may be unchanged or may contain undefined data. A future read of this area may not report an error, even though the data is erroneous. 10.17.7 Handle Streaming Error bit The Handle Streaming Error bit specifies to the device that this command starts at the LBA of a recently reported error section, so the device may attempt to continue its corresponding error recovery sequence where it left off earlier. This mechanism allows the host to schedule error recovery and defect management for content critical data. 10.17.8 Streaming Logs The Streaming Data Transfer feature set requires two error logs and one performance log. These logs are accessed via the Read Log Ext command; the information included in the error logs is volatile and is not maintained across power cycles, hard resets, or sleep. These error logs are 512 bytes in length and retain the last 31 errors that occurred during any Streaming Data transfer. Deskstar 7K80 Hard Disk Drive Specification 108

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258

Deskstar 7K80 Hard Disk Drive Specification
108
10.17.4
Not Sequential bit
The Not Sequential bit specifies that the next read stream command with the same Stream ID may not be sequential
in LBA space.
This information helps the device with pre-fetching decisions.
10.17.5
Read Continuous bit
If the Read Continuous bit is set to one for the command, the device shall transfer the requested amount of data to
the host within the Command Completion Time Limit even if an error occurs.
The data sent to the host by the device
in an error condition is vendor specific.
10.17.6
Write Continuous bit
If the Write Continuous bit is set to one for the command, and an error is encountered, the device shall complete the
request without posting an error.
If an error cannot be resolved within the Command Completion Time Limit, the
erroneous section on the media may be unchanged or may contain undefined data.
A future read of this area may
not report an error, even though the data is erroneous.
10.17.7
Handle Streaming Error bit
The Handle Streaming Error bit specifies to the device that this command starts at the LBA of a recently reported
error section, so the device may attempt to continue its corresponding error recovery sequence where it left off
earlier.
This mechanism allows the host to schedule error recovery and defect management for content critical data.
10.17.8
Streaming Logs
The Streaming Data Transfer feature set requires two error logs and one performance log.
These logs are accessed
via the Read Log Ext command; the information included in the error logs is volatile and is not maintained across
power cycles, hard resets, or sleep.
These error logs are 512 bytes in length and retain the last 31 errors that occurred
during any Streaming Data transfer.