Hitachi HDS728080PLAT20 Specifications - Page 234

Write Log Ext 3Fh

Page 234 highlights

12.48 Write Log Ext (3Fh) Table 161: Write Log Ext Command (3Fh) Command Block Output Registers Register 7 6 5 4 3 2 1 0 Data Low Data High Current Feature Previous Sector Count Current Previous V V V V V V V V V V V V V V V V Sector Number Current Previous V V V V V V V V Cylinder Current Low Previous V V V V V V V V V V V V V V V V Cylinder Current High Previous Device/Head - 1 - D - - - - Command 0 0 1 1 1 1 1 1 76 CRC UNC 0V Error Register 54 3 2 1 0 0 IDN 0 ABT T0N AMN 0V 0 V 0 0 Command Block Input Registers Register 7 6 5 4 3 2 1 0 Data Low Data High Error See below Sector Count HOB=0 HOB=1 Sector Number HOB=0 HOB=1 Cylinder HOB=0 Low HOB=1 Cylinder HOB=0 High HOB=1 Device/Head Status See below ... Status Register 7 654 3 2 1 0 BSY RDY DF DSC DRQ COR IDX ERR 0 V0V - 0 - V This command writes a specified number of 512 byte data sectors to the specific log. The device shall interrupt for each DRQ block transferred. Output parameters to the device Sector Count Current The number of sectors to be written to the specified log low order, bits (7:0). Sector Count Previous The number of sectors to be written to the specified log high orders, bits (15:8). If the number of sectors is greater than the number indicated in the Log directory, which is available in Log number zero, the device shall return command aborted. The log transferred to the device shall be stored by the device starting at the first sector in the specified log. Sector Number Current The log to be written as described in Table 100: "Log Address Definition" on page 152. If the host attempts to write to a read only log address, the device shall return command aborted. Cylinder Low Current The first sector of the log to be written low order, bits (7:0). Cylinder Low Previous The first sector of the log to be written high order, bits (15:8). If the feature set associated with the log specified in the Sector Number register is not supported or enabled, or if the values in the Sector Count, Sector Number or Cylinder Low registers are invalid, the device shall return command aborted. If the host attempts to write to a read only log address, the device shall return command aborted. Deskstar 7K80 Hard Disk Drive Specification 230

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258

Deskstar 7K80 Hard Disk Drive Specification
230
12.48
Write Log Ext (3Fh)
Table 161: Write Log Ext Command
(3Fh)
This command writes a specified number of 512 byte data sectors to the specific log. The device shall interrupt for
each DRQ block transferred.
Output parameters to the device
Sector Count Current
The number of sectors to be written to the specified log low order, bits (7:0).
Sector Count Previous
The number of sectors to be written to the specified log high orders, bits (15:8). If
the number of sectors is greater than the number indicated in the Log directory,
which is available in Log number zero, the device shall return command aborted.
The log transferred to the device shall be stored by the device starting at the first
sector in the specified log.
Sector Number Current
The log to be written as described in Table 100: “Log Address Definition” on
page 152. If the host attempts to write to a read only log address, the device shall
return command aborted.
Cylinder Low Current
The first sector of the log to be written low order, bits (7:0).
Cylinder Low Previous
The first sector of the log to be written high order, bits (15:8).
If the feature set associated with the log specified in the Sector Number register is not supported or enabled, or if
the values in the Sector Count, Sector Number or Cylinder Low registers are invalid, the device shall return com-
mand aborted. If the host attempts to write to a read only log address, the device shall return command aborted.
Command Block Output Registers
Command Block Input Registers
Register
7 6 5 4 3 2 1 0
Register
7 6 5 4 3 2 1 0
Data Low
- - - - - - - -
Data Low
- - - - - - - -
Data High
- - - - - - - -
Data High
- - - - - - - -
Feature
Current
- - - - - - - -
Error
See below
Previous
- - - - - - - -
Sector
Count
Current
V V V V V V V V
Sector
Count
HOB=0
- - - - - - - -
Previous
V V V V V V V V
HOB=1
- - - - - - - -
Sector
Number
Current
V V V V V V V V
Sector
Number
HOB=0
- - - - - - - -
Previous
- - - - - - - -
HOB=1
- - - - - - - -
Cylinder
Low
Current
V V V V V V V V
Cylinder
Low
HOB=0
- - - - - - - -
Previous
V V V V V V V V
HOB=1
- - - - - - - -
Cylinder
High
Current
- - - - - - - -
Cylinder
High
HOB=0
- - - - - - - -
Previous
- - - - - - - -
HOB=1
- - - - - - - -
Device/Head
- 1 - D - - - -
Device/Head
- - - - - - - -
Command
0 0 1 1 1 1 1 1
Status
See below ...
Error Register
Status Register
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
CRC UNC 0 IDN 0 ABT T0N AMN
BSY RDY DF DSC DRQ COR IDX ERR
0
V
0
V
0
V
0
0
0
V
0
V
-
0
-
V