12.42.7 Error reporting The following table shows the values returned in the Status and Error Registers when specific error conditions are encountered by a device. Table 155: S.M.A.R.T. Error Codes Error condition A S.M.A.R.T. FUNCTION SET command was received by the device without the required key being loaded into the Cylinder High and Cylinder Low registers. A S.M.A.R.T. FUNCTION SET command was received by the device with a subcommand value in the Features Register that is either invalid or not supported by this device. A S.M.A.R.T. FUNCTION SET command subcommand other than S.M.A.R.T. ENABLE OPERATIONS was received by the device while the device was in a "S.M.A.R.T. Disabled" state. The device is unable to read its Attribute Values or Attribute Thresholds data structure The device is unable to write to its Attribute Values data structure. Status Register 51h 51h 51h 51h 51h Error Register 04h 04h 04h 10h or 40h 10h Deskstar 7K80 Hard Disk Drive Specification 221