IBM 6500-V5P Maintenance Manual - Page 321
Circuit Board: Power Supply, Removal, Installation
![]() |
View all IBM 6500-V5P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 321 highlights
Circuit Board: Power Supply Circuit Board: Power Supply CAUTION To prevent injury from electric shock, wait at least one minute after powering off before removing the power supply board. ATTENTION Do not touch components on the board during removal or installation. Lift and handle the board only by the loops provided for this purpose. Removal 1. Prepare the printer for maintenance (page 313). 2. Cabinet Model: Remove the paper guide assembly (page 348). Pedestal Model: Remove the top cover assembly (page 327). 3. Mark then disconnect all cable assemblies going to and from the power supply board. (See page 406, item 3.) 4. Loosen-do not remove-the screws securing the power supply board to top rear wall of the card cage. (See page 406, item 15.) 5. Grasp the power supply by the handling loops, tilt it forward, and lift it out of the printer. Installation 1. Reverse steps 2 through 5 of the removal procedure. 2. Models 6500-v15 and -v20: adjust the coil temperature if the original power supply board was replaced by a new or refurbished power supply (page 383). 3. Cabinet Model: Install the paper guide assembly (page 348). Pedestal Model: Install the top cover assembly (page 327). 4. Return the printer to normal operation (page 314). 321
![](/manual_guide/products/ibm-6500v10-maintenance-manual-719aa36/321.png)