IBM 6500-V5P Maintenance Manual - Page 344
Motor Assembly, Platen Open, Removal
View all IBM 6500-V5P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 344 highlights
Motor Assembly, Platen Open Motor Assembly, Platen Open Removal 1. Prepare the printer for maintenance (page 313). 2. Cabinet Model: Remove the paper guide assembly (page 348). Pedestal Model: Remove the top cover assembly (page 327). 3. Cabinet Model: Remove the card cage fan (page 331). 4. Remove the platen open belt cover by squeezing the top and bottom to release the plastic tabs from the slots in the side plate (page 413, Figure 45, item 24). 5. Using a 5/32 inch hex key, loosen the upper motor mount screw (page 416, Figure 46, item 24). 6. Trace the platen open motor cables back to connector P106 on the controller board, releasing the cables from all tie-wraps. (See cable routing diagrams on page 282 and page 283.) 7. Remove the platen open cable connector from connector P106. (See page 323.) 8. Remove the 5/32 inch upper motor mount screw, platen spring post, and platen belt spring (page 416, Figure 46, items 24 through 26). 9. Remove the 5/16 inch lower motor mount screw (page 416, Figure 46, item 15). 10. Remove the platen open motor assembly. 344