Error Code/Symptom 262 (DRAM parity configuration error) 289 (DIMM has been disabled the user or system, see "Memory settings" on page 98) 301 (Keyboard or keyboard controller error) 303 (Keyboard controller error) 602 (Invalid diskette boot record) 604 (Diskette drive error) 605 (Unlock failure) 662 (Diskette drive configuration error) 762 (Coprocessor configuration error) 962 (Parallel port error) 11XX (System board serial port 1 or 2 error) 1762 (Fixed Disk Configuration error) FRU/Action 1. Run Configuration/Setup 2. Battery/CMOS Chip 3. System Board 1. Run Configuration/Setup, if disabled by user 2. Disabled DIMM, if not disabled by user. 3. Processor Board 1. Keyboard 2. System Board 1. Keyboard 2. System Board 1. Diskette 2. Cable 3. Diskette Drive 1. Run Configuration/Setup and Diagnostics 2. Diskette Drive 3. Drive Cable 4. System Board 1. Diskette Drive 2. Drive Cable 3. System Board 1. Run Configuration/Setup and Diagnostics 2. Diskette Drive 3. Drive Cable 4. System Board 1. Run Configuration/Setup 2. Battery/CMOS Chip 3. Processor 1. Disconnect external cable on parallel port. 2. Run Configuration/Setup 3. System Board 1. Disconnect external cable on serial port. 2. Run Configuration/Setup 3. System Board 1. Fixed Disk Cables 2. Run Configuration/Setup 3. Fixed Disk Adapter 4. Fixed Disk Drive 5. System Board 282 Netfinity Server HMM