IBM 86607SU Hardware Maintenance Manual - Page 291
Error Code/Symptom, FRU/Action, Fixed Disk Cables, Configuration/Setup, Remove Failing PCI
UPC - 087944501329
View all IBM 86607SU manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 291 highlights
Error Code/Symptom 178X (Fixed Disk error) 1800 (No more hardware interrupt available for PCI adapter) 1801 (No room for PCI option ROM) 1802 (No more I/O space available for PCI adapter) 1803 (No more memory (above 1MB for PCI adapter) 1804 (No more memory (below 1MB for PCI adapter) 1805 (PCI option ROM checksum error) 1806 (PCI to PCI Bridge error) 1807, 1808, 1810 (General PCI error) 1962 (Drive does not contain a valid boot sector) 2400 (Video controller test failure) 2462 (Video memory configuration error) FRU/Action 1. Fixed Disk Cables 2. Run Diagnostics 3. Fixed Disk Adapter 4. Fixed Disk Drive 5. System Board 1. Run Configuration/Setup 2. Failing Adapter 3. System Board 1. Run Configuration/Setup 2. Failing Adapter 3. System Board 1. Run Configuration/Setup 2. Failing Adapter 3. System Board 1. Run Configuration/Setup 2. Failing Adapter 3. System Board 1. Run Configuration/Setup 2. Move the failing adapter to slot 1 or 2 3. Failing Adapter 4. System Board 1. Remove Failing PCI Card 2. System Board 1. Run Configuration/Setup 2. Move the failing adapter to slot 1 or 2 3. Failing Adapter 4. System Board 1. Remove Failing PCI Card 2. System Board 1. Verify a bootable operating system is installed 2. Run Diagnostics 3. Hard Disk Drive Cable 4. System Board 5. Hard Disk Drive 1. Video Adapter (if installed) 2. System Board 1. Video Adapter (if installed) 2. System Board Netfinity 5500 - Type 8660 283