Intel S2600IP Service Guide - Page 104
Mass Storage Controller Configuration
View all Intel S2600IP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 104 highlights
BIOS Setup Utilities 5. NUMA Optimized Option Values: Enabled Disabled Help Text: If enabled, BIOS includes ACPI tables that are required for NUMA-aware Operating Systems. Comments: This option is only present for boards which have two or more processor sockets. When a multi-socket board has only a single processor installed, this option is grayed out and set as Disabled. When enabled, the SRAT and SLIT ACPI tables are provided that show the locality of systems resources, especially memory, which allows a "NUMA Aware" OS to optimize which processor threads are used by processes which can benefit by having the best access to those resources. Mass Storage Controller Configuration The Mass Storage Configuration screen allows the user to configure the Mass Storage controllers that are integrated into the server board on which the BIOS is executing. This includes only onboard Mass Storage controllers. Mass Storage controllers on add-in cards are not included in this screen, nor are other storage mechanisms such as USB-attached storage devices or Network Attached Storage. There are two types of onboard controller configured in this screen, the AHCI SATA controller and the Storage Control Unit (SCU) with SATA or SAS drive support and RAID support. There are also informational displays of AHCI and SCU controller configuration, and SATA Drive Information when applicable. If the presence of an Intel® Storage Module is detected, the type of Storage Module is displayed as information-only. To access this screen from the Main screen, select Advanced > Mass Storage Controller Configuration. To move to another screen, press the key to return to the Advanced screen, then select the desired screen. 92 Intel® Server System R2000IP Service Guide