Intel S2600IP Service Guide - Page 141

Server Management Screen

Page 141 highlights

BIOS Setup Utilities This option is only displayed when the BMC support this feature on the node. Console Redirection ►System Information ►BMC LAN Configuration Figure 108. Server Management Screen Screen Field Descriptions: 1. Assert NMI on SERR Option Values: Enabled Disabled Help Text: On SERR, generate an NMI and log an error. Note: [Enabled] must be selected for the Assert NMI on PERR setup option to be visible. Comments: This option allows the system to generate an NMI when an SERR occurs, which is a method Legacy Operating System error handlers may use instead of processing a Machine Check. 2. Assert NMI on PERR Option Values: Enabled Disabled Help Text: On PERR, generate an NMI and log an error. Note: This option is only active if the Assert NMI on SERR option has [Enabled] selected. Comments: This option allows the system to generate an NMI when a PERR occurs, which is a method Legacy Operating System error handlers may use instead of processing a Machine Check. 3. Reset on CATERR Option Values: Enabled Disabled Help Text: When enabled system gets reset upon encountering Catastrophic Error (CATERR); when disabled system does not get reset on CATERR. Intel® Server System R2000IP Service Guide 129

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192

BIOS Setup Utilities
Intel
®
Server System R2000IP Service Guide
129
This option is only displayed when the BMC support this feature on the node.
Console Redirection
System Information
BMC LAN Configuration
Figure 108. Server Management Screen
Screen Field Descriptions:
1.
Assert NMI on SERR
Option Values:
Enabled
Disabled
Help Text:
On SERR, generate an NMI and log an error.
Note
: [Enabled] must be selected for the Assert NMI on PERR setup option to be visible.
Comments: This option allows the system to generate an NMI when an SERR occurs, which is a
method Legacy Operating System error handlers may use instead of processing a Machine Check.
2.
Assert NMI on PERR
Option Values:
Enabled
Disabled
Help Text:
On PERR, generate an NMI and log an error.
Note
: This option is only active if the Assert NMI on SERR option has [Enabled] selected.
Comments: This option allows the system to generate an NMI when a PERR occurs, which is a
method Legacy Operating System error handlers may use instead of processing a Machine Check.
3.
Reset on CATERR
Option Values:
Enabled
Disabled
Help Text:
When enabled system gets reset upon encountering Catastrophic Error (CATERR); when
disabled system does not get reset on CATERR.