Intel S2600IP Service Guide - Page 184
Appendix A: Technical Reference
View all Intel S2600IP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 184 highlights
Appendix A: Technical Reference Appendix A: Technical Reference Power Supply Input Voltages 750W power supply module 100 - 127 V at 50/60 Hz 8.2 A 200 - 240 V at 50/60 Hz 4.4 A Power Supply Output Voltages The following table lists the total wattage available from the power subsystem for each voltage. For information about calculating the power usage for your configuration, please use the Power Budget Tool. Table 7. Power Supply Output Capability Voltage Maximum Current 12V 62.0A 12VSB 2.1A System Environmental Limits Parameter Table 8. System Environmental Limits Limits Temperature Humidity Shock Operating Non-Operating 10º C to 35º C1 (50º F to 95º F) with the maximum rate of change not to exceed 10°C per hour -40º C to 70º C (-40º F to 158º F) Non-Operating 50% to 90%, non-condensing with a maximum wet bulb of 28° C (at temperatures from 25° C to 35° C) Operating Unpackaged Packaged Half sine, 2g, 11 mSec Trapezoidal, 25g, velocity change is based on packaged weight Product Weight: ≥ 40 to < 80 Non-palletized Free Fall Height = 18 inches Palletized (single product) Free Fall Height = NA Vibration 172 Intel® Server System R2000IP Service Guide