Intel S2600IP Service Guide - Page 140
Option, Disabled, Enable
![]() |
View all Intel S2600IP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 140 highlights
BIOS Setup Utilities Main Advanced Security Server Management Boot Options Boot Manager Assert NMI on SERR Assert NMI on PERR Enabled / Disabled Enabled / Disabled Reset on CATERR Reset on ERR2 Enabled / Disabled Enabled / Disabled Resume on AC Power Loss Power Restore Delay Power Restore Delay Value Stay Off / Last State / Power On Disabled / Auto / Fixed [25 - 300s, 25 is default] Clear System Event Log Enabled / Disabled FRB-2 Enable Enabled / Disabled OS Boot Watchdog Timer OS Boot Watchdog Timer Policy OS Boot Watchdog Timer Timeout Enabled / Disabled Power off / Reset 5 minutes / 10 minutes / 15 minutes / 20 minutes Plug & Play BMC Detection Enabled / Disabled EuP LOT6 Off-Mode Shutdown Policy Enabled / Disabled Enabled / Disabled ►Shutdown Policy Option Values: Enabled Disabled Help Text: Enable/Disable Shutdown Policy. Comments: This option is designed for multiple-node system and to control the policy that BMC should shutdown one node if it detected over-current or over-temperature condition. The BIOS and the BMC will synchronize the policy during the BIOS POST and current value of the BMC will be displayed in BIOS Setup. 128 Intel® Server System R2000IP Service Guide
![](/manual_guide/products/intel-s2600ip-service-guide-2152727/140.png)