Intel S2600IP Service Guide - Page 159

IP Source, IPv6 Source, Dynamic, Static

Page 159 highlights

BIOS Setup Utilities In either case, the Intel® RMM4 section IP Source or IPv6 Source will determine whether the IPv4 or IPv6 address fields are display-only or can be edited. 11. IP Source Option Values: Static Dynamic Help Text: Select RMM4 IP source: If [Static], IP parameters may be edited. If [Dynamic], these fields are display-only and IP address is acquired automatically (DHCP). Comments: This specifies the IP Source for IPv4 addressing for the Intel® RMM4 DMN LAN connection. There is a separate IP Source field for the Baseboard LAN configuration. When IPv4 addressing is used, the initial value for this field is acquired from the BMC, and its setting determines whether the other Intel® RMM4 DMN LAN IPv4 addressing fields are display-only (when Dynamic) or can be edited (when Static). When IPv6 addressing is enabled, this field is grayed out and inactive. 12. IP Address Option Values: [Entry Field 0.0.0.0, 0.0.0.0 is default] Help Text: View/Edit IP Address. Press to edit. Comments: This specifies the IPv4 Address for the Intel® RMM4 DMN LAN. There is a separate IPv4 Address field for the Baseboard LAN configuration. When IPv4 addressing is used, the initial value for this field is acquired from the BMC. The setting of IP Source determines whether this field is display-only (when Dynamic) or can be edited (when Static). When IPv6 addressing is enabled, this field is grayed out and inactive. 13. Subnet Mask Option Values: [Entry Field 0.0.0.0, 0.0.0.0 is default] Help Text: View/Edit Subnet Mask. Press to edit. Comments: This specifies the IPv4 addressing Subnet Mask for the Intel® RMM4 DMN LAN. There is a separate IPv4 Subnet Mask field for the Baseboard LAN configuration. Intel® Server System R2000IP Service Guide 147

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192

BIOS Setup Utilities
Intel
®
Server System R2000IP Service Guide
147
In either case, the Intel
®
RMM4 section
IP Source
or
IPv6 Source
will determine whether the
IPv4 or IPv6 address fields are display-only or can be edited.
11.
IP Source
Option Values: Static
Dynamic
Help Text:
Select RMM4 IP source: If [Static], IP parameters may be edited. If [Dynamic], these
fields are display-only and IP address is acquired automatically (DHCP).
Comments:
This specifies the IP Source for IPv4 addressing for the Intel
®
RMM4
DMN LAN connection. There is a separate IP Source field for the Baseboard LAN configuration.
When IPv4 addressing is used, the initial value for this field is acquired from the BMC, and its
setting determines whether the other Intel
®
RMM4 DMN LAN IPv4 addressing fields are
display-only (when
Dynamic
) or can be edited (when
Static
).
When IPv6 addressing is enabled, this field is grayed out and inactive.
12.
IP Address
Option Values:
[Entry Field 0.0.0.0,
0.0.0.0
is default]
Help Text:
View/Edit IP Address. Press <Enter> to edit.
Comments:
This specifies the IPv4 Address for the Intel
®
RMM4 DMN LAN. There
is a separate IPv4 Address field for the Baseboard LAN configuration.
When IPv4 addressing is used, the initial value for this field is acquired from the BMC. The
setting of
IP Source
determines whether this field is display-only (when
Dynamic
) or can be
edited (when
Static
).
When IPv6 addressing is enabled, this field is grayed out and inactive.
13.
Subnet Mask
Option Values:
[Entry Field 0.0.0.0,
0.0.0.0
is default]
Help Text:
View/Edit Subnet Mask. Press <Enter> to edit.
Comments: This specifies the IPv4 addressing Subnet Mask for the Intel
®
RMM4 DMN LAN.