Intel S2600IP Service Guide - Page 146

Console Redirection, System Information

Page 146 highlights

BIOS Setup Utilities Option Values: Enabled Disabled Help Text: Enable/disable Ecodesign EuP LOT6 "Deep Sleep" Off-Mode for near-zero energy use when powered off. Comments: This option controls whether the system goes into "Deep Sleep" or more conventional S5 "Soft-Off" when powered off. "Deep Sleep" state uses less energy than S5, but S5 can start up faster and can allow a Wake on LAN action (which cannot be done from a Deep Sleep state). This option will not appear on platforms which do not support EuP LOT6 Off-Mode. For details on which platform do support it 15. Shutdown Policy Option Values: Enabled Disabled Help Text: Enable/Disable Shutdown Policy. Comments: This option is designed for multiple-node system and to control the policy that BMC should shutdown one node if it detected over-current or over-temperature condition. The BIOS and the BMC will synchronize the policy during the BIOS POST and current value of the BMC will be displayed in BIOS Setup. This option is only displayed when the BMC support this feature on the node. 16. Console Redirection Option Values: Help Text: View/Configure Console Redirection information and settings. Comments: Selection only. Position to this line and press the key to go to the Console Redirection group of configuration settings. 17. System Information Option Values: Help Text: View System Information. Comments: Selection only. Position to this line and press the key to go to the System Information group of configuration settings. 18. BMC LAN Configuration 134 Intel® Server System R2000IP Service Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192

BIOS Setup Utilities
134
Intel
®
Server System R2000IP Service Guide
Option Values: Enabled
Disabled
Help Text:
Enable/disable Ecodesign EuP LOT6 “Deep Sleep” Off
-Mode for near-zero energy use
when powered off.
Comments:
This option controls whether the system goes into “Deep Sleep” or more
conventional S5 “Soft
-
Off” when powered off. “Deep Sleep” state uses less energy than S5, but
S5 can start up faster and can allow a Wake on LAN action (which cannot be done from a Deep
Sleep state).
This option will not appear on platforms which do not support EuP LOT6 Off-Mode. For details
on which platform do support it
15.
Shutdown Policy
Option Values: Enabled
Disabled
Help Text:
Enable/Disable Shutdown Policy.
Comments:
This option is designed for multiple-node system and to control the
policy that BMC should shutdown one node if it detected over-current or over-temperature
condition. The BIOS and the BMC will synchronize the policy during the BIOS POST and
current value of the BMC will be displayed in BIOS Setup.
This option is only displayed when the BMC support this feature on the node.
16.
Console Redirection
Option Values:
<None>
Help Text:
View/Configure Console Redirection information and settings.
Comments:
Selection only.
Position to this line and press the <Enter> key to go to the
Console Redirection
group of configuration settings.
17.
System Information
Option Values:
<None>
Help Text:
View System Information.
Comments:
Selection only.
Position to this line and press the <Enter> key to go to the
System Information
group of configuration settings.
18.
BMC LAN Configuration