Intel S2600IP Service Guide - Page 106
Various SATA/SAS Capable Controller configurations require the installation of Intel
View all Intel S2600IP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 106 highlights
BIOS Setup Utilities Option Values: One of these strings: Controller is disabled 2 ports of 6Gb/s SATA 2 ports of 6Gb/s SATA & 4 ports of 3Gb/s SATA Help Text: Comments: Information only. This is a display showing which ports are available through the onboard AHCI capable SATA controller, if the controller is enabled. This information is also displayed during POST in the POST Diagnostic Screen The number of SATA ports available from the integrated AHCI-capable SATA Controller is dependent on the specific server board installed in the system. Different server board designs expose different SATA port configurations. The Platform ID (Board ID) is displayed in the Main Screen 2. SATA/SAS Controller Configuration Option Values: One of these strings: Controller is disabled 4 ports in SATA mode 4 ports in SAS mode 8 ports in SATA mode 8 ports in SAS mode Help Text: Comments: Information only. This is a display showing the number of ports which are available through the SCU controller, and whether they are configured for SATA or SAS. This information is also displayed during POST in the POST Diagnostic Screen Various SATA/SAS Capable Controller configurations require the installation of Intel® RAID C600 Upgrade Keys: 4 port SATA requires no key or AXXRKSATA4R5 key 4 port SAS requires AXXRKSAS4 or AXXRKSAS4R5 key 8 port SATA requires AXXRKSATA8 or AXXRKSATA8R5 key 8 port SAS requires AXXRKSAS8 or AXXRKSAS8R5 key 3. AHCI Capable SATA Controller 94 Intel® Server System R2000IP Service Guide