Intel SBXL52 Hardware Maintenance Manual - Page 105
the option., program. Whenever memory or an option is changed, you must update
View all Intel SBXL52 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 105 highlights
✏ NOTE See "System" on page 104 to determine which components should be replaced by a field service technician. Option problems Symptom FRU/action An Intel option that was just installed does not work. 1. Verify that: • You followed the installation instructions that came with the option. • The option is installed correctly. • You have not loosened any other installed options or cables and that all option hardware and cable connections are secure. • If the failing option is a SCSI storage expansion unit: - The cables for the SCSI expansion unit are connected correctly. - If the SCSI storage expansion unit has been removed, verify that the socket is terminated correctly. - The external SCSI expansion unit is turned on. You must turn on the external SCSI expansion unit before turning on the computer. • You updated the configuration information in the Configuration/Setup Utility program. Whenever memory or an option is changed, you must update the configuration. 2. If the option comes with its own test instructions, use those instructions to test the option. 3. Replace the option you just installed. ✏ NOTE See "System" on page 104 to determine which components should be replaced by a field service technician. Power problems Symptom FRU/action Power switch does not work and reset button, if supported, does work. 1. Reseat connector. 2. Front bezel with customer card. 3. System board. Symptom-to-FRU index 91