Intel SBXL52 Hardware Maintenance Manual - Page 84

Programmable Interval Timer, Flash BIOS.

Page 84 highlights

✏ NOTE See "System" on page 104 to determine which components should be replaced by a field service technician. Beep/symptom FRU/action 1-1-2 1. Optional microprocessor (if installed) (Microprocessor register test failed) 2. Microprocessor 3. System board 1-1-3 (CMOS write/read test failed) 1. Battery 2. System board 1-1-4 (BIOS ROM checksum failed) 1. Flash BIOS. 2. DIMM. 3. System board. 1-2-1 (Programmable Interval Timer failed) • System board 1-2-2 (DMA initialization failed) • System board 1-2-3 (DMA page register write/read failed) • System board 1-2-4 (RAM refresh verification failed) 1. DIMM 2. System board 1-3-1 (first 64K RAM test failed) 1. DIMM 2. System board 1-3-2 (first 64K RAM parity test failed) 1. DIMM 2. System board 2-1-1 (Secondary DMA register failed) • System board 2-1-2 (Primary DMA register failed) • System board 2-1-3 (Primary interrupt mask register failed) • System board 2-1-4 • System board (Secondary interrupt mask register failed) 2-2-1 (Interrupt vector loading failed) • System board 2-2-2 (Keyboard controller failed) 1. Keyboard 2. System board 3. Management module 70 SBXL52: Hardware Maintenance Manual and Troubleshooting Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126

70
SBXL52: Hardware Maintenance Manual and Troubleshooting Guide
NOTE
See “System” on page 104 to determine which components should be replaced by a field service
technician.
Beep/symptom
FRU/action
1-1-2
(Microprocessor register test failed)
1.
Optional microprocessor (if installed)
2.
Microprocessor
3.
System board
1-1-3
(CMOS write/read test failed)
1.
Battery
2.
System board
1-1-4
(BIOS ROM checksum failed)
1.
Flash BIOS.
2.
DIMM.
3.
System board.
1-2-1
(Programmable Interval Timer
failed)
System board
1-2-2
(DMA initialization failed)
System board
1-2-3
(DMA page register write/read
failed)
System board
1-2-4
(RAM refresh verification failed)
1.
DIMM
2.
System board
1-3-1
(first 64K RAM test failed)
1.
DIMM
2.
System board
1-3-2
(first 64K RAM parity test failed)
1.
DIMM
2.
System board
2-1-1
(Secondary DMA register failed)
System board
2-1-2
(Primary DMA register failed)
System board
2-1-3
(Primary interrupt mask register
failed)
System board
2-1-4
(Secondary interrupt mask register
failed)
System board
2-2-1
(Interrupt vector loading failed)
System board
2-2-2
(Keyboard controller failed)
1.
Keyboard
2.
System board
3.
Management module