Intel SBXL52 Hardware Maintenance Manual - Page 94

Microprocessor 2 is not functioning, Microprocessor 1 failed

Page 94 highlights

✏ NOTE See "System" on page 104 to determine which components should be replaced by a field service technician. Error code/symptom FRU/action 2462 (Video memory configuration error) 1. Verify that the keyboard/mouse/video select button LED on the front of the blade server is on, indicating that the blade server is connected to the shared SBCE monitor. 2. Verify that the monitor is connected correctly to the SBCE unit. 3. Video adapter (if installed). 4. System board. 5962 (IDE CD-ROM drive configuration error) 1. Run the Configuration/Setup Utility program. 2. CD-ROM drive. 3. CD-ROM power cable. 4. IDE cable. 5. System board. 6. Battery. 8603 (Pointing-device error) 1. Pointing device 2. System board 0001200 (Machine check architecture error) 1. Microprocessor 1 2. Optional microprocessor 2 3. System board 00012000 (Microprocessor machine check) 1. Microprocessor 2. System board 00019501 (Microprocessor 1 is not functioning check VRM and microprocessor LEDs) 1. Microprocessor 1 2. System board 00019502 (Microprocessor 2 is not functioning - check VRM and microprocessor LEDs) 1. Microprocessor 2 2. System board 00019701 (Microprocessor 1 failed) 1. Microprocessor 1 2. System board 00019702 (Microprocessor 2 failed) 1. Microprocessor 2 2. System board 00151200 (microprocessor machine check) 1. Run the Configuration/Setup Utility program. 2. Microprocessor (check error LED for failing microprocessor). 3. System board. 00180200 (No more I/O space available for adapter) 1. Run the Configuration/Setup Utility program. 2. Failing adapter. 3. System board. 01295085 (ECC checking hardware test error) 1. System board 2. Microprocessor 80 SBXL52: Hardware Maintenance Manual and Troubleshooting Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126

80
SBXL52: Hardware Maintenance Manual and Troubleshooting Guide
2462
(Video memory configuration error)
1.
Verify that the keyboard/mouse/video select button LED on the
front of the blade server is on, indicating that the blade server is
connected to the shared SBCE monitor.
2.
Verify that the monitor is connected correctly to the SBCE unit.
3.
Video adapter (if installed).
4.
System board.
5962
(IDE CD-ROM drive configuration error)
1.
Run the Configuration/Setup Utility program.
2.
CD-ROM drive.
3.
CD-ROM power cable.
4.
IDE cable.
5.
System board.
6.
Battery.
8603
(Pointing-device error)
1.
Pointing device
2.
System board
0001200
(Machine check architecture error)
1.
Microprocessor 1
2.
Optional microprocessor 2
3.
System board
00012000
(Microprocessor machine check)
1.
Microprocessor
2.
System board
00019501
(Microprocessor 1 is not functioning -
check VRM and microprocessor LEDs)
1.
Microprocessor 1
2.
System board
00019502
(Microprocessor 2 is not functioning –
check VRM and microprocessor LEDs)
1.
Microprocessor 2
2.
System board
00019701
(Microprocessor 1 failed)
1.
Microprocessor 1
2.
System board
00019702
(Microprocessor 2 failed)
1.
Microprocessor 2
2.
System board
00151200
(microprocessor machine check)
1.
Run the Configuration/Setup Utility program.
2.
Microprocessor (check error LED for failing microprocessor).
3.
System board.
00180200
(No more I/O space available for
adapter)
1.
Run the Configuration/Setup Utility program.
2.
Failing adapter.
3.
System board.
01295085
(ECC checking hardware test error)
1.
System board
2.
Microprocessor
NOTE
See “System” on page 104 to determine which components should be replaced by a field service
technician.
Error code/symptom
FRU/action