Intel SBXL52 Hardware Maintenance Manual - Page 91
Service Processor failure, Memory test error.
View all Intel SBXL52 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 91 highlights
✏ NOTE See "System" on page 104 to determine which components should be replaced by a field service technician. Error code/symptom FRU/action 151 (Real time clock error) 1. Run diagnostics. 2. Battery. 3. System board. 161 (Real time clock battery error) 1. Run the Configuration/Setup Utility program. 2. Battery. 3. System board. 162 1. Run the Configuration/Setup Utility program. (Device configuration error) ✏ NOTE ✏ NOTE If unable to enter Configuration/Setup Utility program, view Be sure to load the default settings system event log in SBCE management module. and any additional desired settings; then, save the configuration. 2. Battery. 3. Failing device. 4. System board. 163 (Real-time clock error) 1. Run the Configuration/Setup Utility program. 2. Battery. 3. System board. 164 (Memory configuration changed.) 1. Run the Configuration/Setup Utility program. 2. DIMM. 3. System board. 165 (Service Processor failure) • System board 184 (Power-on password damaged) 1. Run the Configuration/Setup Utility program. 2. System board. 185 (Drive startup sequence information corrupted) 1. Run the Configuration/Setup Utility program. 2. System board. 189 (An attempt was made to access the server with invalid passwords) • Run the Configuration/Setup Utility program, and enter the administrator password. 201 1. DIMM (Memory test error.) If the server does 2. System board not have the latest level of BIOS installed, update the BIOS to the latest level and run the diagnostic program again. 229 (Cache error) 1. Microprocessor 2. Optional microprocessor (if installed) 262 (DRAM parity configuration error) 1. Run the Configuration/Setup Utility program. 2. Battery. 3. System board. Symptom-to-FRU index 77