Intel SR1670HV Service Guide - Page 22

Cable Connections

Page 22 highlights

1.6.2 RJ-45 LAN Ports 1 and 2 LEDs Product Introduction Figure 6. RJ-45 Ports 1 and 2 LEDs Table 5. RJ-45 Ports 1 and 2 LEDs Descriptions ACT/LINK LED SPEED LED Status Description Status Description OFF No link OFF 10 Mbps connection GREEN Linked Orange 100 Mbps connection BLINKING Data activity Green 1 Gbps connection 1.6.3 HDD Status LED LED Power Active Figure 7. HDD Status LED Table 6. HDD LED Status Definitions Status Description Green Light ON Power On (detection HDD present) Red Light ON RAID HDD fail (HDD plug-in ready but detection error) G/R Blinking RAID rebuilding OFF HDD not found Green Blink Data read/write to HDD 1.7 Cable Connections NOTE: The bundled system cables are pre-connected before shipment. You do not need to disconnect these cables unless you must remove pre-installed components for servicing or to install additional devices. Refer to Chapter 4, "System Service" for detailed information on the connections. Intel® Server System SR1670HV Service Guide 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157

Product Introduction
Intel
®
Server System SR1670HV Service Guide
7
1.6.2
RJ-45 LAN Ports 1 and 2 LEDs
Figure 6. RJ-45 Ports 1 and 2 LEDs
Table 5. RJ-45 Ports 1 and 2 LEDs Descriptions
ACT/LINK LED
SPEED LED
Status
Description
Status
Description
OFF
No link
OFF
10 Mbps connection
GREEN
Linked
Orange
100 Mbps connection
BLINKING
Data activity
Green
1 Gbps connection
1.6.3
HDD Status LED
Figure 7. HDD Status LED
Table 6. HDD LED Status Definitions
LED
Status
Description
Power
Green Light ON
Red Light ON
G/R Blinking
OFF
Power On (detection HDD present)
RAID HDD fail (HDD plug-in ready but detection error)
RAID rebuilding
HDD not found
Active
Green Blink
Data read/write to HDD
1.7
Cable Connections
NOTE:
The bundled system cables are pre-connected before shipment. You do not need to
disconnect these cables unless you must remove pre-installed components for servicing or to
install additional devices.
Refer to Chapter 4, “System Service” for detailed information on the
connections.