Intel SR1670HV Service Guide - Page 37

Installing the BMC Management Module

Page 37 highlights

Hardware Setup 2.5 Installing the BMC Management Module Complete the following steps to install the BMC Management Module onto the server board. 1. Locate the BMC_FW1 header on the server board. Figure 28. BMC_FW1 Header 2. Orient and press the management card in place. Figure 29. Orienting the Management Module Card 3. Insert the LAN cable plug into the Server Management LAN port located above the USB ports. Figure 30. Server Management LAN Port NOTE: With the BMC Management Module installed, each time the AC power cord is plugged into the server, there will be a delay of 45-60 seconds before the server powers on. During this time, the Blue System ID LED will turn on, and the power button will be disabled. This power on delay is required to reset the BMC controller on the BMC Management Module. Once the BMC reset is complete, the System ID LED will turn off, and the power button functionality will be reenabled. 22 Intel® Server System SR1670HV Service Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157

Hardware Setup
22
Intel
®
Server System SR1670HV Service Guide
2.5
Installing the BMC Management Module
Complete the following steps to install the BMC Management Module onto the server
board.
1.
Locate the BMC_FW1 header on the server board.
Figure 28. BMC_FW1 Header
2.
Orient and press the management card in place.
Figure 29. Orienting the Management Module Card
3.
Insert the LAN cable plug into the Server Management LAN port located above the
USB ports.
Figure 30. Server Management LAN Port
NOTE:
With the BMC Management Module installed, each time the AC power cord is plugged
into the server, there will be a delay of 45-60 seconds before the server powers on. During this
time, the Blue System ID LED will turn on, and the power button will be disabled. This power on
delay is required to reset the BMC controller on the BMC Management Module. Once the BMC
reset is complete, the System ID LED will turn off, and the power button functionality will be re-
enabled.