Chapter 5 - Troubleshooting and Maintaining the 6820 Diagnostic Information (continued) Field Id Length Description Stored as 2 1 2 2 20 2 2 1 2 2 30 2 Voltage extreme history stores min/max 24 2 bytes V A2D conversions over printer life 24 V voltage error. Voltages greater than 1 byte 10% considered errors. A2D error count Form number at last voltage error 2 bytes 24 V error count 2 bytes Last high and low voltage extremes on 12 V 2 bytes input over last 50 reports. Extremes stored as 8-bit A2D conversions Voltage extreme stores min/max 12 V A2D 2 bytes conversions over printer life 12 V error. Voltages less than 10.5 V and greater than 14.5 V are considered errors. A2D value is recorded 1 byte Page number at last 12 V error 2 bytes 12 V error count 2 bytes Temperature, maximum and minimum over last 50 reports. Set A2D value 2 bytes 2 1 2 2 40 2 Temperature, min/max over printer life. Set 2 bytes A2D value Temperature error. Last A2D conversion 1 byte below -10 or above 60 °C recorded Page number at last temperature error 2 bytes Total number of temperature errors 2 bytes Total number of head jams 2 bytes binary Total Length 11 bytes 11 bytes 11 bytes 6820 Series 80-Column Printer User Manual 93

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166

Chapter 5 — Troubleshooting and Maintaining the 6820
6820 Series 80-Column Printer User Manual
93
2
Voltage extreme history stores min/max 24
V A2D conversions over printer life
2 bytes
1
24 V voltage error. Voltages greater than
10% considered errors. A2D error count
1 byte
2
Form number at last voltage error
2 bytes
2
24 V error count
2 bytes
20
2
Last high and low voltage extremes on 12 V
input over last 50 reports. Extremes stored
as 8-bit A2D conversions
2 bytes
11 bytes
2
Voltage extreme stores min/max 12 V A2D
conversions over printer life
2 bytes
1
12 V error. Voltages less than 10.5 V and
greater than 14.5 V are considered errors.
A2D value is recorded
1 byte
2
Page number at last 12 V error
2 bytes
2
12 V error count
2 bytes
30
2
Temperature, maximum and minimum
over last 50 reports. Set A2D value
2 bytes
11 bytes
2
Temperature, min/max over printer life. Set
A2D value
2 bytes
1
Temperature error. Last A2D conversion
below -10 or above 60 °C recorded
1 byte
2
Page number at last temperature error
2 bytes
2
Total number of temperature errors
2 bytes
40
2
Total number of head jams
2 bytes binary
11 bytes
Diagnostic Information (continued)
Field
Id
Length
Description
Stored as
Total
Length