Chapter 5 - Troubleshooting and Maintaining the 6820 Diagnostic Information (continued) Field Id Length Description 1 Command 0 = Stop 2 = Print 4 = Print/LF 6 = Seek 8 = Slow Seek 10 = Change Speed 12 = Feed 14 = Wait Stored as bits 0-3 Total Length 1 1 2 2 60 4 4 4 4 4 Speed 00 = Init 01 = Low 10 = High bits 4-5 Direction bit 6 1 = Left 0 = Right Home Switch bit 7 0 = No Error 1 = High Error Acceleration or deceleration stop motor value when jam occurred 1 byte binary Ambient temperature when had jam occurred. Set A2D value 1 byte Form number where head jam occurred 2 bytes binary Carriage position where head jam occurred 2 bytes binary in 1/720 in IrDA rxFramesOK - total frames received 4 bytes OK 46 bytes IrDA rxFrameCrcErr - total frames received 4 bytes with CRC error IrDA rxTotalBytes - total bytes received OK 4 bytes IrDA rxFramesDiscardBuf - total frames 4 bytes discarded due to no buffer space IrDA rxBroadcastFrames - total broadcast 4 bytes frames received OK 94 6820 Series 80-Column Printer User Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166

Chapter 5 — Troubleshooting and Maintaining the 6820
94
6820 Series 80-Column Printer User Manual
1
Command
0 = Stop
2 = Print
4 = Print/LF
6 = Seek
8 = Slow Seek
10 = Change Speed
12 = Feed
14 = Wait
Speed
00 = Init
01 = Low
10 = High
Direction
1 = Left
0 = Right
Home Switch
0 = No Error
1 = High Error
bits 0-3
bits 4-5
bit 6
bit 7
1
Acceleration or deceleration stop motor
value when jam occurred
1 byte binary
1
Ambient temperature when had jam
occurred. Set A2D value
1 byte
2
Form number where head jam occurred
2 bytes binary
2
Carriage position where head jam occurred
2 bytes binary in 1/720
in
60
4
IrDA rxFramesOK – total frames received
OK
4 bytes
46 bytes
4
IrDA rxFrameCrcErr – total frames received
with CRC error
4 bytes
4
IrDA rxTotalBytes – total bytes received OK
4 bytes
4
IrDA rxFramesDiscardBuf – total frames
discarded due to no buffer space
4 bytes
4
IrDA rxBroadcastFrames – total broadcast
frames received OK
4 bytes
Diagnostic Information (continued)
Field
Id
Length
Description
Stored as
Total
Length